Literature DB >> 10982646

Biomechanical analysis of effects of foot placement with varying chair height on the motion of standing up.

S Kawagoe1, N Tajima, E Chosa.   

Abstract

Individual experience reveals that posterior foot placement enables one to stand up easily from a chair. However, the way in which foot placement affects this motion has not been investigated in detail. This study was performed to examine the effects of foot placement in the initial stage of the dynamics of standing up from a chair. Subjects wearing light-emitting diode markers and surface electrodes stood up from a chair over force plates, and ground reaction force, joint angle, and muscle activity were measured. The motions required to stand up from chairs 30, 40, or 50 cm in height were analyzed with anterior, vertical, and posterior foot placement. With anterior foot placement, the forward-acceleration components of the ground reaction force were recorded with simultaneous and long-sustained activity of the muscles in order to shift the center of gravity of the body forward even more after lift-off. Our findings indicate that the distance between the center of gravity and the point of application of ground reaction force at lift-off are critical factors in the standing-up motion, and that chairs should be of adequate height as well as having sufficient space under the seat to permit the backward movement of the lower legs.

Mesh:

Year:  2000        PMID: 10982646     DOI: 10.1007/s007760050139

Source DB:  PubMed          Journal:  J Orthop Sci        ISSN: 0949-2658            Impact factor:   1.601


  11 in total

1.  Prolonged weight-shift and altered spinal coordination during sit-to-stand in practitioners of the Alexander Technique.

Authors:  Timothy W Cacciatore; Victor S Gurfinkel; Fay B Horak; Brian L Day
Journal:  Gait Posture       Date:  2011-07-22       Impact factor: 2.840

2.  Association between chair stand strategy and mobility limitations in older adults with symptomatic knee osteoarthritis.

Authors:  Neil A Segal; Elizabeth R Boyer; Robert Wallace; James C Torner; H John Yack
Journal:  Arch Phys Med Rehabil       Date:  2012-10-09       Impact factor: 3.966

3.  Sit-to-stand 3 months after unilateral total knee arthroplasty: comparison of self-selected and constrained conditions.

Authors:  Sara J Farquhar; Kenton R Kaufman; Lynn Snyder-Mackler
Journal:  Gait Posture       Date:  2009-05-27       Impact factor: 2.840

4.  Effect of arm position and foot placement on the five times sit-to-stand test completion times of female adults older than 50 years of age.

Authors:  Shamay S M Ng; Patrick W H Kwong; Michael S P Chau; Isaac C Y Luk; Sam S Wan; Shirley S M Fong
Journal:  J Phys Ther Sci       Date:  2015-06-30

5.  Comparison of center-of-pressure displacement during sit-to-stand according to chair height in children with cerebral palsy.

Authors:  Hye-Young Lee; In-Hee Lee
Journal:  J Phys Ther Sci       Date:  2015-07-22

6.  Immediate effects of quick trunk movement exercise on sit-to-stand movement in children with spastic cerebral palsy: a pilot study.

Authors:  Abbas Abdolrahmani; Hiroyuki Sakita; Ryo Yonetsu; Akira Iwata
Journal:  J Phys Ther Sci       Date:  2017-05-16

7.  Electromyographic activity of quadriceps muscle during sit-to-stand in patients with unilateral knee osteoarthritis.

Authors:  Hamad S Al Amer; Mohamed A Sabbahi; Hesham N Alrowayeh; William J Bryan; Sharon L Olson
Journal:  BMC Res Notes       Date:  2018-06-05

8.  Foot placement and arm position affect the five times sit-to-stand test time of individuals with chronic stroke.

Authors:  Patrick W H Kwong; Shamay S M Ng; Raymond C K Chung; Gabriel Y F Ng
Journal:  Biomed Res Int       Date:  2014-06-16       Impact factor: 3.411

9.  Noninvasive Estimation of Joint Moments with Inertial Sensor System for Analysis of STS Rehabilitation Training.

Authors:  Kun Liu; Jianchao Yan; Yong Liu; Ming Ye
Journal:  J Healthc Eng       Date:  2018-02-11       Impact factor: 2.682

10.  Nondestructive Estimation of Muscle Contributions to STS Training with Different Loadings Based on Wearable Sensor System.

Authors:  Kun Liu; Yong Liu; Jianchao Yan; Zhenyuan Sun
Journal:  Sensors (Basel)       Date:  2018-03-25       Impact factor: 3.576

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.