Mechanical testing of shoulder prostheses and recommendations for glenoid design.

C Anglin1, U P Wyss, D R Pichora.   

Abstract

Glenoid component loosening generates the greatest concern among surgeons performing total shoulder arthroplasty. Laboratory testing of glenoid prostheses may lead to improved design, subsequently leading to a reduction in the incidence of clinical loosening. The goals of this study were to develop a laboratory test method to address glenoid loosening and to apply this method to a variety of prosthesis designs. With use of a biaxial apparatus, glenoid components were cyclically subjected to superoinferior edge loading, mimicking the off-center rocking-horse phenomenon thought to contribute to glenoid loosening clinically. Before and after the rocking test was performed, compression and distraction of the superior and inferior edges were measured with the humeral head displaced to each edge. Rocking performance could not be predicted from initial measurements, indicating the necessity for dynamic loading to evaluate the likelihood of loosening. A roughened fixation surface for outperformed a smooth fixation surface, a curved backing showed almost half the distraction of a flat backing, and a nonconstrained prosthesis distracted less than a more constrained prosthesis.

Entities:  

Mesh:

Year:  2000        PMID: 10979530     DOI: 10.1067/mse.2000.105451

Source DB:  PubMed          Journal:  J Shoulder Elbow Surg        ISSN: 1058-2746            Impact factor:   3.019


  20 in total

1.  Does an increase in modularity improve the outcomes of total shoulder replacement? Comparison across design generations.

Authors:  Bradley Schoch; Jean-David Werthel; Cathy Schleck; John W Sperling; Robert H Cofield
Journal:  Int Orthop       Date:  2015-08-06       Impact factor: 3.075

2.  Consequences of scapular anatomy for reversed total shoulder arthroplasty.

Authors:  Bart Middernacht; Pieter-Jan De Roo; Georges Van Maele; Lieven F De Wilde
Journal:  Clin Orthop Relat Res       Date:  2008-03-06       Impact factor: 4.176

3.  Stability of two versus three peripheral pegs of the glenoid component in modern total shoulder arthroplasty.

Authors:  Eugene F Stautberg; Daniel C Jupiter; Arsalan Amin; Ali A Qadeer; Omer A Ilahi
Journal:  Int Orthop       Date:  2017-08-24       Impact factor: 3.075

Review 4.  Glenoid or not glenoid component in primary osteoarthritis.

Authors:  Kany Jean
Journal:  Eur J Orthop Surg Traumatol       Date:  2012-11-30

5.  The glenoid in total shoulder arthroplasty.

Authors:  Mark Schrumpf; Travis Maak; Sommer Hammoud; Edward V Craig
Journal:  Curr Rev Musculoskelet Med       Date:  2011-12

6.  Reverse total shoulder arthroplasty: radiological and clinical result using an eccentric glenosphere.

Authors:  Carlo Felice De Biase; Marco Delcogliano; Mario Borroni; A Castagna
Journal:  Musculoskelet Surg       Date:  2012-04-20

7.  Construct damage and loosening around glenoid implants: A longitudinal micro-CT study of five cadaver specimens.

Authors:  Gregory S Lewis; Jacob B Brenza; Emmanuel M Paul; April D Armstrong
Journal:  J Orthop Res       Date:  2015-12-28       Impact factor: 3.494

8.  Number of pegs influence focal stress distributions and micromotion in glenoid implants: a finite element study.

Authors:  Abdul Hadi Abdul Wahab; Mohammed Rafiq Abdul Kadir; Muhammad Noor Harun; Tunku Kamarul; Ardiyansyah Syahrom
Journal:  Med Biol Eng Comput       Date:  2016-06-02       Impact factor: 2.602

9.  Posterior glenoid wear in total shoulder arthroplasty: eccentric anterior reaming is superior to posterior augment.

Authors:  Tim Wang; Geoffrey D Abrams; Anthony W Behn; Derek Lindsey; Nicholas Giori; Emilie V Cheung
Journal:  Clin Orthop Relat Res       Date:  2015-08-05       Impact factor: 4.176

10.  Failure mechanism of the all-polyethylene glenoid implant.

Authors:  Junaid Sarah; Gupta Sanjay; Sanghavi Sanjay; Anglin Carolyn; Roger Emery; Amis Andrew; Hansen Ulrich
Journal:  J Biomech       Date:  2009-11-25       Impact factor: 2.712

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.