Literature DB >> 10977011

Comparison of continuous subcutaneous insulin infusion and multiple daily injection regimens using insulin lispro in type 1 diabetic patients on intensified treatment: a randomized study. The Study Group for the Development of Pump Therapy in Diabetes.

H Hanaire-Broutin1, V Melki, S Bessières-Lacombe, J P Tauber.   

Abstract

OBJECTIVE: To compare the efficacy of 2 intensified insulin regimens, continuous subcutaneous insulin infusion (CSII) and multiple daily injections (MDI), by using the short-acting insulin analog lispro in type 1 diabetic patients. RESEARCH DESIGN AND METHODS: A total of 41 C-peptide-negative type 1 diabetic patients (age 43.5+/-10.3 years; 21 men and 20 women, BMI 24.0+/-2.4 kg/m2, diabetes duration 20.0+/-11.3 years) on intensified insulin therapy (MDI with regular insulin or lispro, n = 9, CSII with regular insulin, n = 32) were included in an open-label randomized crossover study comparing two 4-month periods of intensified insulin therapy with lispro: one period by MDI and the other by CSII. Blood glucose (BG) was monitored before and after each of the 3 meals each day.
RESULTS: The basal insulin regimen had to be optimized in 75% of the patients during the MDI period (mean number of NPH injections per day = 2.65). HbA1c values were lower when lispro was used in CSII than in MDI (7.89+/-0.77 vs. 8.24+/-0.77%, P<0.001). BG levels were lower with CSII (165+/-27 vs. 175+/-33 mg/dl, P<0.05). The SD of all the BG values (73+/-15 vs. 82+/-18 mg/dl, P<0.01) was lower with CSII. The frequency of hypoglycemic events, defined as BG levels <60 mg/dl, did not differ significantly between the 2 modalities (CSII 3.9+/-4.2 per 14 days vs. MDI 4.3+/-3.9 per 14 days). Mean insulin doses were significantly lower with CSII than with MDI (38.5+/-9.8 vs. 47.3+/-14.9 U/day. respectively, P< 0.0001).
CONCLUSIONS: When used with external pumps versus MDI, lispro provides better glycemic control and stability with much lower doses of insulin and does not increase the frequency of hypoglycemic episodes.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10977011     DOI: 10.2337/diacare.23.9.1232

Source DB:  PubMed          Journal:  Diabetes Care        ISSN: 0149-5992            Impact factor:   19.112


  26 in total

1.  A review of the management of implanted medical devices for diabetes: trends and directions.

Authors:  Carl Edman; Darrel Drinan
Journal:  J Diabetes Sci Technol       Date:  2008-11

Review 2.  Physical activity and type 1 diabetes: time for a rewire?

Authors:  Sheri R Colberg; Remmert Laan; Eyal Dassau; David Kerr
Journal:  J Diabetes Sci Technol       Date:  2015-01-06

3.  Glycaemic control with continuous subcutaneous insulin infusion compared with intensive insulin injections in patients with type 1 diabetes: meta-analysis of randomised controlled trials.

Authors:  John Pickup; Martin Mattock; Sally Kerry
Journal:  BMJ       Date:  2002-03-23

Review 4.  Insulin lispro: a pharmacoeconomic review of its use in diabetes mellitus.

Authors:  Christopher J Dunn; Greg L Plosker
Journal:  Pharmacoeconomics       Date:  2002       Impact factor: 4.981

5.  Accuracy of a new patch pump based on a microelectromechanical system (MEMS) compared to other commercially available insulin pumps: results of the first in vitro and in vivo studies.

Authors:  Sophie Borot; Sylvia Franc; Justine Cristante; Alfred Penfornis; Pierre-Yves Benhamou; Bruno Guerci; Hélène Hanaire; Eric Renard; Yves Reznik; Chantal Simon; Guillaume Charpentier
Journal:  J Diabetes Sci Technol       Date:  2014-07-30

Review 6.  The evidence base for diabetes technology: appropriate and inappropriate meta-analysis.

Authors:  John C Pickup
Journal:  J Diabetes Sci Technol       Date:  2013-11-01

7.  Optimal control of blood glucose: the diabetic patient or the machine?

Authors:  Larry Brown; Elazer R Edelman
Journal:  Sci Transl Med       Date:  2010-04-14       Impact factor: 17.956

Review 8.  Novel Insulin Delivery Technologies in Women with Pregestational Type 1 Diabetes: A Review of the Literature.

Authors:  Erin Drever; Denice S Feig
Journal:  Obstet Med       Date:  2013-03-01

Review 9.  Continuous subcutaneous insulin infusion versus multiple daily insulin injections in patients with diabetes mellitus: systematic review and meta-analysis.

Authors:  K Jeitler; K Horvath; A Berghold; T W Gratzer; K Neeser; T R Pieber; A Siebenhofer
Journal:  Diabetologia       Date:  2008-03-20       Impact factor: 10.122

10.  [Guidelines for insulin pump therapy in children and adults].

Authors:  Marietta Stadler; Sandra Zlamal-Fortunat; Ingrid Schütz-Fuhrmann; Birgit Rami-Merhar; Edith Schober; Alexandra Kautzky-Willer; Raimund Weitgasser; Rudolf Prager; Martin Bischof
Journal:  Wien Klin Wochenschr       Date:  2012-12       Impact factor: 1.704