Literature DB >> 10975599

Fluospheres for cardiovascular phenotyping genetically modified mice.

C Richer1, V Domergue, M Gervais, P Bruneval, J F Giudicelli.   

Abstract

Assessment of systemic and regional hemodynamic phenotypes in genetically engineered mice by nonradioactive methods is yet an unsolved problem. We therefore investigated whether the reference sample method using fluorescent microspheres (FMs), already validated in rats, might be used for this purpose in C57BL/6 and in apolipoprotein E (ApoE)-deficient mice. FMs were injected into the left ventricle of instrumented anesthetized mice. In 10-week-old C57BL/6, cardiac output was 18-19 ml/min, and its regional distribution under basal conditions was approximately 1.5% (brain), 3.5% (heart), 9. 1% (left kidney), 9.8% (right kidney), 1% (spleen), and 0.8% (stomach) (i.e., values similar to those previously reported with radioactive microspheres). Proper mixing of FMs was achieved as both kidneys had identical flows; distribution of two differently labeled FMs injected simultaneously was shown to be identical by an agreement study, and FM trapping in the capillary bed was demonstrated both histologically and by the recovery in the lungs of 90% of intravenously injected FMs. In addition, identical values for cardiac output and its distribution were obtained in different age-matched groups of C57BL/6. The FM technique also proved to be able to evidence angiotensin II and isoprenaline classic systemic and regional hemodynamic effects. Finally, applied to 30-week-old ApoE-deficient mice and age-matched C57BL/6, the FM technique showed no major hemodynamic difference between the two groups, except for coronary blood flow, which was significantly decreased in ApoE-deficient mice. In conclusion, we demonstrated for the first time the feasibility, accuracy, and reliability of the FM technique at characterizing the cardiovascular phenotype of genetically engineered mice.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10975599     DOI: 10.1097/00005344-200009000-00017

Source DB:  PubMed          Journal:  J Cardiovasc Pharmacol        ISSN: 0160-2446            Impact factor:   3.105


  7 in total

1.  Measuring bone blood supply in mice using fluorescent microspheres.

Authors:  Maria A Serrat
Journal:  Nat Protoc       Date:  2009-11-05       Impact factor: 13.491

2.  Accelerated dual-contrast first-pass perfusion MRI of the mouse heart: development and application to diet-induced obese mice.

Authors:  Nivedita K Naresh; Xiao Chen; Rene J Roy; Patrick F Antkowiak; Brian H Annex; Frederick H Epstein
Journal:  Magn Reson Med       Date:  2014-04-23       Impact factor: 4.668

Review 3.  Magnetic resonance imaging and spectroscopy of the murine cardiovascular system.

Authors:  Ashwin Akki; Ashish Gupta; Robert G Weiss
Journal:  Am J Physiol Heart Circ Physiol       Date:  2013-01-04       Impact factor: 4.733

4.  A modified fluorescent microsphere-based approach for determining resting and hyperemic blood flows in individual murine skeletal muscles.

Authors:  Trevor R Cardinal; James B Hoying
Journal:  Vascul Pharmacol       Date:  2007-04-19       Impact factor: 5.773

5.  First-pass contrast-enhanced myocardial perfusion MRI in mice on a 3-T clinical MR scanner.

Authors:  Marcus Makowski; Christian Jansen; Ian Webb; Amedeo Chiribiri; Eike Nagel; Rene Botnar; Sebastian Kozerke; Sven Plein
Journal:  Magn Reson Med       Date:  2010-10-06       Impact factor: 4.668

6.  Quantitative myocardial perfusion in mice based on the signal intensity of flow sensitized CMR.

Authors:  Sumeda Abeykoon; Michelle Sargent; Janaka P Wansapura
Journal:  J Cardiovasc Magn Reson       Date:  2012-10-24       Impact factor: 5.364

7.  Hyperemic stress myocardial perfusion cardiovascular magnetic resonance in mice at 3 Tesla: initial experience and validation against microspheres.

Authors:  Roy Jogiya; Markus Makowski; Alkystsis Phinikaridou; Ashish S Patel; Christian Jansen; Niloufar Zarinabad; Amedeo Chiribiri; Rene Botnar; Eike Nagel; Sebastian Kozerke; Sven Plein
Journal:  J Cardiovasc Magn Reson       Date:  2013-07-21       Impact factor: 5.364

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.