PURPOSE: To determine the imaging characteristics of a new computed tomographic (CT) contrast material with both hepatocyte-selective and blood-pool components (iodinated triglyceride (ITG)-dual) versus standard iohexol. MATERIALS AND METHODS: VX2 carcinoma was inoculated in seven rabbits. Animals underwent nonenhanced, iohexol-enhanced (600 mg of iodine per kilogram of body weight), and ITG-dual-enhanced (blood-pool moiety, 100 mg of iodine per kilogram; hepatocyte-selective moiety, 100 or 200 mg of iodine per kilogram, injected 90 minutes apart) helical CT. Livers were removed, preserved in formalin, suspended in agar, and sectioned transversely at 3-mm intervals. Attenuation values for normal liver and tumors were obtained, and blinded readers evaluated images for lesions by using a modified free-response receiver operating characteristic (ROC) method. RESULTS: A total of 47 separate tumor sites were detected at pathologic examination. ITG-dual-enhanced scans obtained with 300 mg of iodine per kilogram demonstrated similar liver opacification to iohexol-enhanced scans obtained with 600 mg of iodine per kilogram, but with less lesion enhancement, which resulted in better liver-to-lesion contrast. Blinded readers had a higher sensitivity, accuracy, and area under the ROC curve for ITG-dual-enhanced scans as compared with iohexol-enhanced scans (P: <.01). CONCLUSION: ITG-dual-enhanced CT quantitatively and qualitatively improved liver lesion detection versus iohexol-enhanced CT. Future clinical trials with various human tumor types after potential approval for human use are needed to determine the ultimate role of this or other dual-mechanism contrast materials.
PURPOSE: To determine the imaging characteristics of a new computed tomographic (CT) contrast material with both hepatocyte-selective and blood-pool components (iodinated triglyceride (ITG)-dual) versus standard iohexol. MATERIALS AND METHODS: VX2 carcinoma was inoculated in seven rabbits. Animals underwent nonenhanced, iohexol-enhanced (600 mg of iodine per kilogram of body weight), and ITG-dual-enhanced (blood-pool moiety, 100 mg of iodine per kilogram; hepatocyte-selective moiety, 100 or 200 mg of iodine per kilogram, injected 90 minutes apart) helical CT. Livers were removed, preserved in formalin, suspended in agar, and sectioned transversely at 3-mm intervals. Attenuation values for normal liver and tumors were obtained, and blinded readers evaluated images for lesions by using a modified free-response receiver operating characteristic (ROC) method. RESULTS: A total of 47 separate tumor sites were detected at pathologic examination. ITG-dual-enhanced scans obtained with 300 mg of iodine per kilogram demonstrated similar liver opacification to iohexol-enhanced scans obtained with 600 mg of iodine per kilogram, but with less lesion enhancement, which resulted in better liver-to-lesion contrast. Blinded readers had a higher sensitivity, accuracy, and area under the ROC curve for ITG-dual-enhanced scans as compared with iohexol-enhanced scans (P: <.01). CONCLUSION:ITG-dual-enhanced CT quantitatively and qualitatively improved liver lesion detection versus iohexol-enhanced CT. Future clinical trials with various humantumor types after potential approval for human use are needed to determine the ultimate role of this or other dual-mechanism contrast materials.
Authors: Inneke Willekens; Tony Lahoutte; Nico Buls; Christian Vanhove; Rudi Deklerck; Axel Bossuyt; Johan de Mey Journal: Mol Imaging Biol Date: 2008-12-06 Impact factor: 3.488
Authors: Sumeet Virmani; Kathleen R Harris; Barbara Szolc-Kowalska; Tatjana Paunesku; Gayle E Woloschak; Fred T Lee; Robert J Lewandowski; Kent T Sato; Robert K Ryu; Riad Salem; Andrew C Larson; Reed A Omary Journal: J Vasc Interv Radiol Date: 2008-04-18 Impact factor: 3.464
Authors: Lucia Martiniova; Melanie S Kotys; David Thomasson; Daniel Schimel; Edwin W Lai; Marcelino Bernardo; Maria J Merino; James F Powers; Jan Ruzicka; Richard Kvetnansky; Peter L Choyke; Karel Pacak Journal: J Magn Reson Imaging Date: 2009-03 Impact factor: 4.813
Authors: Lucia Martiniova; Daniel Schimel; Edwin W Lai; Andrea Limpuangthip; Richard Kvetnansky; Karel Pacak Journal: Methods Date: 2009-06-09 Impact factor: 3.608