Literature DB >> 10966690

Sedation procedures in MR imaging: safety, effectiveness, and nursing effect on examinations.

D A Bluemke1, S N Breiter.   

Abstract

PURPOSE: To measure the safety and effectiveness of conscious sedation in order to assess utilization and the effect on magnetic resonance (MR) imaging examinations.
MATERIALS AND METHODS: A database of conscious sedation records for MR imaging at the Johns Hopkins Hospital, Baltimore, Md, from 1991 to 1998 was searched. Safety data according to medication and procedure duration for each nurse were tabulated for 6,093 patient records. Data were analyzed by using quality control statistical measures to determine time utilization and effectiveness. Break-even costs for the procedure were determined.
RESULTS: Of 6,093 patients scheduled for examination, 4,761 patients (78.1%) received conscious sedation by the MR conscious sedation service. Complications were observed in 20 of the 4,761 patients (0.42%). No deaths occurred. The most common complication was oxygen desaturation (n = 8). Diagnostic and complete MR examinations were performed in 4,453 of the 4,761 patients (93.5%). The mean time to sedate the patient (+/- SD) was 23.6 minutes +/- 15.2 for specialized MR sedation nurses and 26.8 minutes +/- 20.1 for general radiology nurses (P: <.001). For inpatient nurses from the inpatient hospital units, the sedation time was considerably longer (47.3 minutes +/- 36.6, P: <.001) and more variable. Break-even costs were 37% ($11 vs $8 for MR room time) more for general radiology nurses than for specialized MR sedation nurses performing the procedure.
CONCLUSION: Conscious sedation is safe and has a high effectiveness rate. A highly specialized nursing staff reduces procedure variability and cost.

Entities:  

Mesh:

Year:  2000        PMID: 10966690     DOI: 10.1148/radiology.216.3.r00se45645

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  19 in total

1.  Risks of propofol sedation/anesthesia for imaging studies in pediatric research: eight years of experience in a clinical research center.

Authors:  Ruwan Kiringoda; Audrey E Thurm; Matthew E Hirschtritt; Deloris Koziol; Robert Wesley; Susan E Swedo; Naomi P O'Grady; Zenaide M N Quezado
Journal:  Arch Pediatr Adolesc Med       Date:  2010-06

2.  Safety and effectiveness of moderate sedation for radiologic non-vascular intervention.

Authors:  Tae-Hoon Kim
Journal:  Korean J Radiol       Date:  2006 Apr-Jun       Impact factor: 3.500

Review 3.  Motion-compensation techniques in neonatal and fetal MR imaging.

Authors:  C Malamateniou; S J Malik; S J Counsell; J M Allsop; A K McGuinness; T Hayat; K Broadhouse; R G Nunes; A M Ederies; J V Hajnal; M A Rutherford
Journal:  AJNR Am J Neuroradiol       Date:  2012-05-10       Impact factor: 3.825

4.  Effect of team training on improving MRI study completion rates and no-show rates.

Authors:  Alexander Norbash; Kent Yucel; William Yuh; Gheorghe Doros; Amna Ajam; Elvira Lang; Stephen Pauker; Nina Mayr
Journal:  J Magn Reson Imaging       Date:  2016-04-06       Impact factor: 4.813

Review 5.  Chloral hydrate as a sedating agent for neurodiagnostic procedures in children.

Authors:  Choong Yi Fong; Chee Geap Tay; Lai Choo Ong; Nai Ming Lai
Journal:  Cochrane Database Syst Rev       Date:  2017-11-03

6.  Pediatric Sedation: Using Secondary Data to Describe Registered Nurse Practice in Radiology.

Authors:  Nancy Crego
Journal:  J Radiol Nurs       Date:  2014-12

Review 7.  [MR urography: principles, examination techniques, indications].

Authors:  M Memarsadeghi; M Riccabona; G Heinz-Peer
Journal:  Radiologe       Date:  2005-10       Impact factor: 0.635

8.  Preparing children with a mock scanner training protocol results in high quality structural and functional MRI scans.

Authors:  Henrica M A de Bie; Maria Boersma; Mike P Wattjes; Sofie Adriaanse; R Jeroen Vermeulen; Kim J Oostrom; Jaap Huisman; Dick J Veltman; Henriette A Delemarre-Van de Waal
Journal:  Eur J Pediatr       Date:  2010-03-13       Impact factor: 3.183

Review 9.  Pediatric MRU--its potential and its role in the diagnostic work-up of upper urinary tract dilatation in infants and children.

Authors:  Michael Riccabona
Journal:  World J Urol       Date:  2004-06-09       Impact factor: 4.226

10.  Safety of cardiac magnetic resonance and contrast angiography for neonates and small infants: a 10-year single-institution experience.

Authors:  Sheela Rangamani; Joby Varghese; Ling Li; Lisa Harvey; James M Hammel; Scott E Fletcher; Kim F Duncan; David A Danford; Shelby Kutty
Journal:  Pediatr Radiol       Date:  2012-08-12
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.