High-speed digital microscopy.

M J Sanderson1.   

Abstract

High-speed imaging is an ideal technique to accurately resolve the temporal and spatial characteristics of rapid events at either the molecular or cellular level. In this article, the digital imaging techniques used to simultaneously acquire transillumination phase-contrast images, at 240 images s(-1) (high-speed), to characterize ciliary beat frequency, and fluorescence images, at 30 images s(-1) (fast), to measure intracellular calcium concentration ([Ca2+]i), are described. With this technique, a precise correlation between the changes in ciliary beat frequency with changes in [Ca2+]i can be made. Simultaneous imaging is achieved by using different wavelengths of light to form the phase-contrast and fluorescent images and selectively directing these light wavelengths to different cameras with dichroic mirrors and bandpass filters. High-speed images compatible with standard video recording equipment are obtained by prematurely resetting the raster scan of a CCD camera with additional vertical synchronization pulses. The fast [Ca2+]i images are determined using the ratiometric dye fura-2 and a recording technique that monitors rapid changes in fluorescence at a single wavelength and uses intermittent reference images for calibration.

Entities:  

Mesh:

Year:  2000        PMID: 10964577     DOI: 10.1006/meth.2000.1022

Source DB:  PubMed          Journal:  Methods        ISSN: 1046-2023            Impact factor:   3.608


  6 in total

1.  Oscillations in ciliary beat frequency and intracellular calcium concentration in rabbit tracheal epithelial cells induced by ATP.

Authors:  Luo Zhang; Michael J Sanderson
Journal:  J Physiol       Date:  2003-02-01       Impact factor: 5.182

2.  Functional imaging of mucociliary phenomena: high-speed digital reflection contrast microscopy.

Authors:  M Ryser; A Burn; Th Wessel; M Frenz; J Ricka
Journal:  Eur Biophys J       Date:  2007-04-17       Impact factor: 1.733

Review 3.  Tubal transport of gametes and embryos: a review of physiology and pathophysiology.

Authors:  Mohammad Ezzati; Ovrang Djahanbakhch; Sara Arian; Bruce R Carr
Journal:  J Assist Reprod Genet       Date:  2014-08-13       Impact factor: 3.412

Review 4.  Technical advances in rhinologic basic science research.

Authors:  Murugappan Ramanathan; Justin H Turner; Andrew P Lane
Journal:  Otolaryngol Clin North Am       Date:  2009-10       Impact factor: 3.346

5.  The role of cGMP in the regulation of rabbit airway ciliary beat frequency.

Authors:  Luo Zhang; Michael J Sanderson
Journal:  J Physiol       Date:  2003-06-20       Impact factor: 5.182

6.  An Automated Measurement of Ciliary Beating Frequency using a Combined Optical Flow and Peak Detection.

Authors:  Woojae Kim; Tae Hwa Han; Hyun Jun Kim; Man Young Park; Ku Sang Kim; Rae Woong Park
Journal:  Healthc Inform Res       Date:  2011-06-30
  6 in total