Measurement of cardiac output by thermal dilution in infants and children.

S D Wyse, J Pfitzner, A Rees, J C Lincoln, M A Branthwaite.   

Abstract

The accuracy of the thermal dilution technique for measuring cardiac output in infants and children has been assessed by comparison with the direct Fick technique. Satisfactory correlation between the two methods has been demonstrated, and it is concluded that a commercially available monitor can be used to determine cardiac output by thermal dilution in acutely sick infants and children. The volume of injectate should be selected according to the weight of the child, and the value displayed by the monitor should be adjusted by the appropriate fraction.

Entities:  

Mesh:

Substances:

Year:  1975        PMID: 1096351      PMCID: PMC470276          DOI: 10.1136/thx.30.3.262

Source DB:  PubMed          Journal:  Thorax        ISSN: 0040-6376            Impact factor:   9.139


  8 in total

1.  Determination of cardiac output in man by a new method based on thermodilution.

Authors:  H H KHALIL
Journal:  Lancet       Date:  1963-06-22       Impact factor: 79.321

2.  Cardiac output measured by thermal dilution of room temperature injectate.

Authors:  E EVONUK; C J IMIG; W GREENFIELD; J W ECKSTEIN
Journal:  J Appl Physiol       Date:  1961-03       Impact factor: 3.531

3.  Thermal dilution curves in the intact animal.

Authors:  A V GOODYER; A HUVOS; W F ECKHARDT; R H OSTBERG
Journal:  Circ Res       Date:  1959-05       Impact factor: 17.367

4.  Thermal-dilution technics.

Authors:  K F HOSIE
Journal:  Circ Res       Date:  1962-03       Impact factor: 17.367

5.  Validity and reproducibility of determination of cardiac output by thermodilution in man.

Authors:  B Olsson; J Pool; P Vandermoten; E Varnauskas; R Wassén
Journal:  Cardiology       Date:  1970       Impact factor: 1.869

6.  Simultaneous determinations of cardiac output by thermal dilution, fiberoptic and dye-dilution methods.

Authors:  R Singh; A J Ranieri; H R Vest; D L Bowers; J F Dammann
Journal:  Am J Cardiol       Date:  1970-05       Impact factor: 2.778

7.  Measurement of cardiac output by thermal dilution in man.

Authors:  M A Branthwaite; R D Bradley
Journal:  J Appl Physiol       Date:  1968-03       Impact factor: 3.531

8.  The effect of section of the carotid sinus and aortic nerves on the cardiac output of the rabbit.

Authors:  P I Korner
Journal:  J Physiol       Date:  1965-09       Impact factor: 5.182

  8 in total
  2 in total

1.  Method of assessing the reproducibility of blood flow measurement: factors influencing the performance of thermodilution cardiac output computers.

Authors:  J D Mackenzie; N E Haites; J M Rawles
Journal:  Br Heart J       Date:  1986-01

Review 2.  Errors in the measurement of cardiac output by thermodilution.

Authors:  T Nishikawa; S Dohi
Journal:  Can J Anaesth       Date:  1993-02       Impact factor: 5.063

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.