[Tissue harmonic imaging in comparison with conventional sonography: effect on image quality and observer variability in the measurement of the intima-media thickness in the common carotid artery].

W A Willinek1, M von Falkenhausen, H Strunk, H H Schild.   

Abstract

OBJECTIVE: The purpose of this study was to determine if tissue harmonic imaging (THI) produced a higher image quality than conventional sonography and if THI reduced the observer availability in the intima media thickness (IMT) measurements of the common carotid artery (ACC). SUBJECTS AND METHODS: A prospective study was performed on 26 healthy volunteers and IMT was assessed by three experienced sonographers in 52 carotid arteries. A 7.5 MHz transducer was used to measure carotid IMT in both harmonic and fundamental modes. Three measurements of IMT were carried out on the far wall of the ACC along a 1 cm-long section proximal to the bifurcation. Image quality was graded from 1-3 (1 = excellent, 2 = good, 3 = poor). IMT measurements using harmonic and fundamental modes were compared and intra- and inter-observer variability were calculated. Statistical analyses were performed using a kappa analysis, ANOVA and the McNemar/Wilcoxon Test.
RESULTS: In the 52 cases image quality was excellent in 51% using THI in comparison to 32% using conventional sonography. Image quality was graded significantly more frequent as excellent using harmonic sonography as compared to conventional sonography (p = 0.001). A significant difference in IMT was found between the measurements obtained by harmonic imaging in comparison to those obtained by conventional imaging (p < 0.0001). Using the harmonic mode inter-observer variability of the IMT measurements was significantly reduced from 8.1% to 5.2% (p < 0.001).
CONCLUSIONS: THI produced a higher image quality with a better visualisation of carotid IMT and reduced significantly the intra- and inter-observer variability in the IMT measurements.

Entities:  

Mesh:

Year:  2000        PMID: 10962992     DOI: 10.1055/s-2000-4653

Source DB:  PubMed          Journal:  Rofo        ISSN: 1438-9010


  6 in total

Review 1.  [Modern gray-scale sonography of the breast].

Authors:  N K Wöhrle; K Hellerhoff; M F Reiser; D-A Clevert
Journal:  Radiologe       Date:  2010-11       Impact factor: 0.635

2.  [Current developments in vascular ultrasound].

Authors:  A Horng; M Reiser; D-A Clevert
Journal:  Radiologe       Date:  2009-11       Impact factor: 0.635

Review 3.  [Latest developments in ultrasound of the liver].

Authors:  D-A Clevert; A Helck; P M Paprottka; F Schwarz; M F Reiser
Journal:  Radiologe       Date:  2011-08       Impact factor: 0.635

4.  Medical ultrasound systems.

Authors:  Jeff Powers; Frederick Kremkau
Journal:  Interface Focus       Date:  2011-05-18       Impact factor: 3.906

5.  [Cardio-pulmonary vascular system. Three-dimensional quantitative evaluation by microcomputed tomography].

Authors:  A C Langheinrich; B Leithauser; W S Rau; R M Bohle
Journal:  Pathologe       Date:  2004-03       Impact factor: 1.011

6.  [Modern ultrasound diagnostics of deep vein thrombosis in lung embolism of unknown origin].

Authors:  D-A Clevert; E M Jung; K Pfister; K Stock; G Schulte-Altedorneburg; C Fink; D-A Clevert; M Reiser
Journal:  Radiologe       Date:  2007-08       Impact factor: 0.635

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.