Literature DB >> 10960405

The effect on intracuff pressure of various nitrous oxide concentrations used for inflating an endotracheal tube cuff.

F Karasawa1, T Ohshima, I Takamatsu, T Ehata, I Fukuda, Y Uchihashi, T Satoh.   

Abstract

UNLABELLED: We sought to determine the optimal concentration of nitrous oxide (N(2)O) for inflating endotracheal tube cuffs, to avoid overinflation and air leaks. Female patients undergoing endotracheal intubation (inner diameter 7.5 mm) during anesthesia with 67% N(2)O were randomly assigned to five groups of 25 subjects each, in which cuffs were inflated with 0% (Air), 30% (N30), 40% (N40), 50% (N50), or 67% (N67) N(2)O. The cuff pressure and the N(2)O concentration in the cuff were measured. In an additional 15 patients (N40-a group), pilot balloons were replaced with metal tubes, and the mouths and noses of the patients were wrapped with tape, to minimize N(2)O efflux into the air. Postoperative sore throats were evaluated in double-blinded interviews. Cuff pressures increased significantly in the Air and N30 groups but decreased in the N67 group. Cuff pressures were <22 mm Hg in the N40 and N50 groups, but the N50 group had air leaks. The N(2)O concentration in the cuff in the N40 group was significantly smaller than that in the N40-a group, suggesting N(2)O rediffusion. The incidence of sore throats (40% in the Air group) was reduced significantly in the N40 and N50 groups. Therefore, 40% N(2)O is optimal for filling the cuff during anesthesia with 67% N(2)O. IMPLICATIONS: Nitrous oxide (N(2)O) diffuses into the cuff, equilibrating at a smaller concentration than the gas mixture with which patients are ventilated. Our data indicate that inflation of the cuff with 40% N(2)O is recommended to prevent both excessive endotracheal cuff pressure and air leaks during anesthesia with 67% N(2)O, reducing postoperative sore throats.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10960405     DOI: 10.1097/00000539-200009000-00040

Source DB:  PubMed          Journal:  Anesth Analg        ISSN: 0003-2999            Impact factor:   5.108


  3 in total

1.  Changes in cuff pressure of endotracheal tube during laparoscopic and open abdominal surgery.

Authors:  Zeynep Baysal Yildirim; Ali Uzunkoy; Ali Cigdem; Suleyman Ganidagli; Abdullah Ozgonul
Journal:  Surg Endosc       Date:  2011-09-10       Impact factor: 4.584

2.  The CobraPLA during anesthesia with controlled ventilation: a clinical trial of efficacy.

Authors:  Sang Beom Nam; Yon Hee Shim; Min Soo Kim; Young Chul You; Youn-Woo Lee; Dong Woo Han; Jong Seok Lee
Journal:  Yonsei Med J       Date:  2006-12-31       Impact factor: 2.759

3.  Effect of endotracheal tube lubrication on cuff pressure increase during nitrous oxide exposure: a laboratory and prospective randomized controlled trial.

Authors:  Moriyoshi Oji; Yukihide Koyama; Hiroyuki Oshika; Masashi Kohno; Yusuke Nakahashi; Sayano Fukushima; Hidemasa Iwakura; Tomio Andoh
Journal:  BMC Anesthesiol       Date:  2019-08-31       Impact factor: 2.217