Literature DB >> 10959960

In situ assembled mass-transport controlling micromembranes and their application in implanted amperometric glucose sensors.

T Chen1, K A Friedman, I Lei, A Heller.   

Abstract

Micromembranes were assembled by sequentially chemisorbing polyanions and polycations on miniature (5 x 10(-4) cm2) enzyme electrodes. The sequential chemisorption process allowed the simultaneous tailoring of their sensitivity, dynamic range, drift, and selectivity. When assembled on tips of 250-microm-diameter gold wires coated with redox polymer-"wired" glucose oxidase, they allowed tailoring of the glucose electrodes for > 2 nA/mM sensitivity; 0-30 mM dynamic range; drift of < or =5% per 24 h at 37 degrees C at 15 mM glucose concentration; and < or =5% current increment by the combination of 0.1 mM ascorbate, 0.2 mM acetaminophen, and 0.5 mM urate. The membranes also retained transition metal ions that bound to and damaged the redox polymer "wiring" the enzyme. The electrodes were tested in the jugular veins and in the intrascapular subcutaneous region of anaesthetized and heparinized nondiabetic Sprague-Dawley rats, in which rapid changes of glycemia were forced by intravenous injections of glucose and insulin. After one-point in vivo calibration of the electrodes, all of the 152 data points were clinically accurate when it was assumed that after insulin injection the glycemia in the subcutaneous fluid lags by 9 min behind that of blood withdrawn from the insulin-injected vein.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10959960     DOI: 10.1021/ac000348c

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  5 in total

1.  Solid-contact potentiometric polymer membrane microelectrodes for the detection of silver ions at the femtomole level.

Authors:  Nastassia Rubinova; Karin Chumbimuni-Torres; Eric Bakker
Journal:  Sens Actuators B Chem       Date:  2006-11-16       Impact factor: 7.460

2.  Kinetic modulation of pulsed chronopotentiometric polymeric membrane ion sensors by polyelectrolyte multilayers.

Authors:  Yida Xu; Chao Xu; Alexey Shvarev; Thomas Becker; Roland De Marco; Eric Bakker
Journal:  Anal Chem       Date:  2007-08-21       Impact factor: 6.986

3.  Microdialysis sampling extraction efficiency of 2-deoxyglucose: role of macrophages in vitro and in vivo.

Authors:  Xiaodun Mou; Julie A Stenken
Journal:  Anal Chem       Date:  2006-11-15       Impact factor: 6.986

4.  Ultra-sensitivity glucose sensor based on field emitters.

Authors:  Huibiao Liu; Xuemin Qian; Shu Wang; Yuliang Li; Yinglin Song; Daoben Zhu
Journal:  Nanoscale Res Lett       Date:  2009-06-14       Impact factor: 4.703

5.  Fabrication of an Extremely Cheap Poly(3,4-ethylenedioxythiophene) Modified Pencil Lead Electrode for Effective Hydroquinone Sensing.

Authors:  Jian-Yu Lu; Yu-Sheng Yu; Tung-Bo Chen; Chiung-Fen Chang; Sigitas Tamulevičius; Donats Erts; Kevin C-W Wu; Yesong Gu
Journal:  Polymers (Basel)       Date:  2021-01-22       Impact factor: 4.329

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.