Literature DB >> 10958187

Investigation of variance reduction techniques for Monte Carlo photon dose calculation using XVMC.

I Kawrakow1, M Fippel.   

Abstract

Several variance reduction techniques, such as photon splitting, electron history repetition, Russian roulette and the use of quasi-random numbers are investigated and shown to significantly improve the efficiency of the recently developed XVMC Monte Carlo code for photon beams in radiation therapy. It is demonstrated that it is possible to further improve the efficiency by optimizing transpon parameters such as electron energy cut-off, maximum electron energy step size, photon energy cut-off and a cut-off for kerma approximation, without loss of calculation accuracy. These methods increase the efficiency by a factor of up to 10 compared with the initial XVMC ray-tracing technique or a factor of 50 to 80 compared with EGS4/PRESTA. Therefore, a common treatment plan (6 MV photons, 10 x 10 cm2 field size, 5 mm voxel resolution, 1% statistical uncertainty) can be calculated within 7 min using a single CPU 500 MHz personal computer. If the requirement on the statistical uncertainty is relaxed to 2%, the calculation time will be less than 2 min. In addition, a technique is presented which allows for the quantitative comparison of Monte Carlo calculated dose distributions and the separation of systematic and statistical errors. Employing this technique it is shown that XVMC calculations agree with EGSnrc on a sub-per cent level for simulations in the energy and material range of interest for radiation therapy.

Mesh:

Year:  2000        PMID: 10958187     DOI: 10.1088/0031-9155/45/8/308

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  30 in total

Review 1.  Monte Carlo systems used for treatment planning and dose verification.

Authors:  Lorenzo Brualla; Miguel Rodriguez; Antonio M Lallena
Journal:  Strahlenther Onkol       Date:  2016-11-25       Impact factor: 3.621

2.  Improved efficiency in Monte Carlo simulation for passive-scattering proton therapy.

Authors:  J Ramos Méndez; J Perl; J Schümann; J Shin; H Paganetti; B Faddegon
Journal:  Phys Med Biol       Date:  2015-06-10       Impact factor: 3.609

3.  A GPU-accelerated Monte Carlo dose calculation platform and its application toward validating an MRI-guided radiation therapy beam model.

Authors:  Yuhe Wang; Thomas R Mazur; Olga Green; Yanle Hu; Hua Li; Vivian Rodriguez; H Omar Wooten; Deshan Yang; Tianyu Zhao; Sasa Mutic; H Harold Li
Journal:  Med Phys       Date:  2016-07       Impact factor: 4.071

4.  ARCHERRT - a GPU-based and photon-electron coupled Monte Carlo dose computing engine for radiation therapy: software development and application to helical tomotherapy.

Authors:  Lin Su; Youming Yang; Bryan Bednarz; Edmond Sterpin; Xining Du; Tianyu Liu; Wei Ji; X George Xu
Journal:  Med Phys       Date:  2014-07       Impact factor: 4.071

5.  Reconstruction of organ dose for external radiotherapy patients in retrospective epidemiologic studies.

Authors:  Choonik Lee; Jae Won Jung; Christopher Pelletier; Anil Pyakuryal; Stephanie Lamart; Jong Oh Kim; Choonsik Lee
Journal:  Phys Med Biol       Date:  2015-02-26       Impact factor: 3.609

6.  Fast patient-specific Monte Carlo brachytherapy dose calculations via the correlated sampling variance reduction technique.

Authors:  Andrew Sampson; Yi Le; Jeffrey F Williamson
Journal:  Med Phys       Date:  2012-02       Impact factor: 4.071

7.  In-air fluence profiles and water depth dose for uncollimated electron beams.

Authors:  Abedelkadar Toutaoui; Amar Nassim Aichouche; Kenza Adjidir Adjidir; Ahmed Chafik Chami
Journal:  J Med Phys       Date:  2008-10

8.  Fast, accurate photon beam accelerator modeling using BEAMnrc: a systematic investigation of efficiency enhancing methods and cross-section data.

Authors:  Margarida Fragoso; Iwan Kawrakow; Bruce A Faddegon; Timothy D Solberg; Indrin J Chetty
Journal:  Med Phys       Date:  2009-12       Impact factor: 4.071

9.  Evaluation of dose prediction errors and optimization convergence errors of deliverable-based head-and-neck IMRT plans computed with a superposition/convolution dose algorithm.

Authors:  I B Mihaylov; J V Siebers
Journal:  Med Phys       Date:  2008-08       Impact factor: 4.071

10.  A fast radiotherapy paradigm for anal cancer with volumetric modulated arc therapy (VMAT).

Authors:  Florian Stieler; Dirk Wolff; Frank Lohr; Volker Steil; Yasser Abo-Madyan; Friedlieb Lorenz; Frederik Wenz; Sabine Mai
Journal:  Radiat Oncol       Date:  2009-10-25       Impact factor: 3.481

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.