Low frequency TENS is less effective than high frequency TENS at reducing inflammation-induced hyperalgesia in morphine-tolerant rats.

K A Sluka1, M A Judge, M M McColley, P M Reveiz, B M Taylor.   

Abstract

Both transcutaneous electrical nerve stimulation (TENS) and morphine are commonly used for relief of pain. Extensive research has been done on the effectiveness of each of these two methods for pain relief when given independently. However, very little literature exists examining the effectiveness of their combined use. Systemically administered morphine activates mu opioid receptors and when administered for prolonged periods results in analgesic tolerance. Low (4 Hz) and high (100 Hz) frequency TENS activate mu- and delta-opioid receptors, respectively, It is thus possible that TENS would be less effective in morphine-tolerant subjects. The current study investigated the effectiveness of high- and low-frequency TENS in the reversal of hyperalgesia in inflamed rats that were morphine-tolerant. Morphine tolerance was induced by subcutaneous implantation of morphine pellets over 10 days. Knee joint inflammation was induced by injection of kaolin and carrageenan into the knee joint cavity. Secondary heat hyperalgesia was tested by measuring the paw withdrawal latency to radiant heat (1) before pellet implantation (either morphine or placebo), (2) after pellet implantation and before inflammation, (3) after inflammation and (4) after TENS. Both high (100 Hz) and low (4 Hz) frequency TENS caused nearly 100% inhibition of secondary hyperalgesia in animals receiving placebo pellets. In contrast, the hyperalgesia in morphine-tolerant animals with knee joint inflammation was unaffected by low frequency TENS but fully reversed by high frequency TENS. These results suggest that patients who are tolerant to morphine may respond better to high frequency TENS than to low frequency TENS. Copyright 2000 European Federation of Chapters of the International Association for the Study of Pain.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10957699     DOI: 10.1053/eujp.2000.0172

Source DB:  PubMed          Journal:  Eur J Pain        ISSN: 1090-3801            Impact factor:   3.931


  21 in total

1.  What makes transcutaneous electrical nerve stimulation work? Making sense of the mixed results in the clinical literature.

Authors:  Kathleen A Sluka; Jan M Bjordal; Serge Marchand; Barbara A Rakel
Journal:  Phys Ther       Date:  2013-05-02

Review 2.  Non-Invasive Neuromodulation for Headache Disorders.

Authors:  Shuhan Zhu; Michael J Marmura
Journal:  Curr Neurol Neurosci Rep       Date:  2016-02       Impact factor: 5.081

3.  Conventional and kilohertz-frequency spinal cord stimulation produces intensity- and frequency-dependent inhibition of mechanical hypersensitivity in a rat model of neuropathic pain.

Authors:  Ronen Shechter; Fei Yang; Qian Xu; Yong-Kwan Cheong; Shao-Qiu He; Andrei Sdrulla; Alene F Carteret; Paul W Wacnik; Xinzhong Dong; Richard A Meyer; Srinivasa N Raja; Yun Guan
Journal:  Anesthesiology       Date:  2013-08       Impact factor: 7.892

4.  Effects of transcutaneous electrical nerve stimulation on pain, pain sensitivity, and function in people with knee osteoarthritis: a randomized controlled trial.

Authors:  Carol Grace T Vance; Barbara A Rakel; Nicole P Blodgett; Josimari Melo DeSantana; Annunziato Amendola; Miriam Bridget Zimmerman; Deirdre M Walsh; Kathleen A Sluka
Journal:  Phys Ther       Date:  2012-03-30

5.  Electroacupuncture reduces the evoked responses of the spinal dorsal horn neurons in ankle-sprained rats.

Authors:  Jae Hyo Kim; Hee Young Kim; Kyungsoon Chung; Jin Mo Chung
Journal:  J Neurophysiol       Date:  2011-03-09       Impact factor: 2.714

6.  Spinal 5-HT(2) and 5-HT(3) receptors mediate low, but not high, frequency TENS-induced antihyperalgesia in rats.

Authors:  Rajan Radhakrishnan; Ellen W King; Janelle K Dickman; Carli A Herold; Natalie F Johnston; Megan L Spurgin; Kathleen A Sluka
Journal:  Pain       Date:  2003-09       Impact factor: 6.961

7.  Transcutaneous electrical nerve stimulation at both high and low frequencies activates ventrolateral periaqueductal grey to decrease mechanical hyperalgesia in arthritic rats.

Authors:  J M DeSantana; L F S Da Silva; M A De Resende; K A Sluka
Journal:  Neuroscience       Date:  2009-07-02       Impact factor: 3.590

8.  Modulation between high- and low-frequency transcutaneous electric nerve stimulation delays the development of analgesic tolerance in arthritic rats.

Authors:  Josimari M Desantana; Valter J Santana-Filho; Kathleen A Sluka
Journal:  Arch Phys Med Rehabil       Date:  2008-04       Impact factor: 3.966

Review 9.  Transcutaneous electrical nerve stimulation (TENS) for fibromyalgia in adults.

Authors:  Mark I Johnson; Leica S Claydon; G Peter Herbison; Gareth Jones; Carole A Paley
Journal:  Cochrane Database Syst Rev       Date:  2017-10-09

10.  Spinal muscarinic receptors are activated during low or high frequency TENS-induced antihyperalgesia in rats.

Authors:  R Radhakrishnan; K A Sluka
Journal:  Neuropharmacology       Date:  2003-12       Impact factor: 5.250

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.