Literature DB >> 10956339

Analysis of ultrasonically extracted interstitial fluid as a predictor of blood glucose levels.

S Mitragotri1, M Coleman, J Kost, R Langer.   

Abstract

Transdermal extraction of clinically relevant analytes offers a potentially noninvasive method of diagnostics. However, development of such a method is limited by the low permeability of skin. In this paper, we present a potential method for noninvasive diagnostics based on ultrasonic skin permeabilization and subsequent extraction of interstitial fluid (ISF) across the skin using vacuum. ISF extracted by this method was collected and analyzed for glucose and other analytes. Glucose concentration in the extracted fluid correlates well with blood glucose concentration over a range of 50-250 mg/dl. A mathematical model describing vacuum-induced transport of ISF through ultrasonically permeabilized skin is presented as well. The model accounts for convective, as well as diffusive, transport processes across blood capillaries, epidermis, and the stratum corneum. The overall predictions of the model compare favorably with the experimental observations.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10956339     DOI: 10.1152/jappl.2000.89.3.961

Source DB:  PubMed          Journal:  J Appl Physiol (1985)        ISSN: 0161-7567


  10 in total

Review 1.  Technologies for continuous glucose monitoring: current problems and future promises.

Authors:  Santhisagar Vaddiraju; Diane J Burgess; Ioannis Tomazos; Faquir C Jain; Fotios Papadimitrakopoulos
Journal:  J Diabetes Sci Technol       Date:  2010-11-01

2.  Detection of trace glucose on the surface of a semipermeable membrane using a fluorescently labeled glucose-binding protein: a promising approach to noninvasive glucose monitoring.

Authors:  Xudong Ge; Govind Rao; Yordan Kostov; Sunsanee Kanjananimmanont; Rose M Viscardi; Hyung Woo; Leah Tolosa
Journal:  J Diabetes Sci Technol       Date:  2013-01-01

3.  Noninvasive ultrasonic glucose sensing with large pigs (approximately 200 pounds) using a lightweight cymbal transducer array and biosensors.

Authors:  Eun-Joo Park; Jacob Werner; Joshua Beebe; Samantha Chan; Nadine Barrie Smith
Journal:  J Diabetes Sci Technol       Date:  2009-05-01

4.  Glucose partition coefficient and diffusivity in the lower skin layers.

Authors:  Enam Khalil; Kosmas Kretsos; Gerald B Kasting
Journal:  Pharm Res       Date:  2006-05-26       Impact factor: 4.200

5.  Rapid sampling of molecules via skin for diagnostic and forensic applications.

Authors:  Sumit Paliwal; Makoto Ogura; Samir Mitragotri
Journal:  Pharm Res       Date:  2010-03-18       Impact factor: 4.200

6.  Noninvasive transcutaneous sampling of glucose by electroporation.

Authors:  S Srinivasa Murthy; V Siva Ram Kiran; S K Mathur; S Narasimha Murthy
Journal:  J Diabetes Sci Technol       Date:  2008-03

Review 7.  Materials for diabetes therapeutics.

Authors:  Kaitlin M Bratlie; Roger L York; Michael A Invernale; Robert Langer; Daniel G Anderson
Journal:  Adv Healthc Mater       Date:  2012-04-05       Impact factor: 9.933

8.  A touch-based multimodal and cryptographic bio-human-machine interface.

Authors:  Shuyu Lin; Jialun Zhu; Wenzhuo Yu; Bo Wang; Kiarash A Sabet; Yichao Zhao; Xuanbing Cheng; Hannaneh Hojaiji; Haisong Lin; Jiawei Tan; Carlos Milla; Ronald W Davis; Sam Emaminejad
Journal:  Proc Natl Acad Sci U S A       Date:  2022-04-04       Impact factor: 12.779

Review 9.  Perspectives on transdermal ultrasound mediated drug delivery.

Authors:  Nadine Barrie Smith
Journal:  Int J Nanomedicine       Date:  2007

10.  Extraction and biomolecular analysis of dermal interstitial fluid collected with hollow microneedles.

Authors:  Philip R Miller; Robert M Taylor; Bao Quoc Tran; Gabrielle Boyd; Trevor Glaros; Victor H Chavez; Raga Krishnakumar; Anupama Sinha; Kunal Poorey; Kelly P Williams; Steven S Branda; Justin T Baca; Ronen Polsky
Journal:  Commun Biol       Date:  2018-10-22
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.