Literature DB >> 10954454

CT versus sonography for monitoring radiofrequency ablation in a porcine liver.

C H Cha1, F T Lee, J M Gurney, B K Markhardt, T F Warner, F Kelcz, D M Mahvi.   

Abstract

OBJECTIVE: The objective of this study was to compare CT and sonography for monitoring radiofrequency (RF) lesions in porcine livers. SUBJECTS AND METHODS: RF lesions (n = 12) were created in three pig livers by applying 13 min of current to a multielectrode RF probe with a target temperature of 95 degrees C. Helical unenhanced CT and corresponding axial sonography were performed before ablation, at 2 min, 8 min, and immediately after ablation. Contrast-enhanced CT was performed after ablation. CT scans and sonograms were evaluated by blinded observers for conspicuity of the RF lesion, edge detection (visibility of liver-lesion interface), and artifacts. Hounsfield units were recorded at every time interval, and radiologic-pathologic correlation for lesion size and configuration was performed.
RESULTS: Mean size of RF lesions was 3. 03 +/- 0.9 cm. On CT, RF lesions had consistently lower attenuation values than surrounding liver (22.2 H lower than liver at 8 min, p < 0.0001). Echogenicity was variable with sonography (hypoechoic = 59%, hyperechoic = 25%, isoechoic = 16%). Unenhanced CT significantly improved conspicuity, edge detection of RF lesions, and decreased artifacts compared with sonography (p < 0.05). Contrast-enhanced CT improved RF lesion detection, border discrimination, and artifacts compared with sonography (p < 0.05). Unenhanced CT had the best correlation to pathologic size (r = 0.74), followed by contrast-enhanced CT (r = 0.72) and sonography (r = 0.56). Contrast-enhanced CT best correlated with lesion shape, but slightly overestimated size because of areas of ischemia peripheral to the RF lesion.
CONCLUSION: In this animal model, unenhanced CT was an effective way to monitor RF ablation compared with sonography because of increased lesion discrimination, reproducible decreased attenuation during ablation, and improved correlation to pathologic size.

Entities:  

Mesh:

Year:  2000        PMID: 10954454     DOI: 10.2214/ajr.175.3.1750705

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  43 in total

1.  Quantifying local stiffness variations in radiofrequency ablations with dynamic indentation.

Authors:  Ryan J DeWall; Tomy Varghese; Christopher L Brace
Journal:  IEEE Trans Biomed Eng       Date:  2011-12-08       Impact factor: 4.538

2.  Shear wave velocity imaging using transient electrode perturbation: phantom and ex vivo validation.

Authors:  Ryan J DeWall; Tomy Varghese; Ernest L Madsen
Journal:  IEEE Trans Med Imaging       Date:  2010-11-11       Impact factor: 10.048

3.  Liver ablation guidance with acoustic radiation force impulse imaging: challenges and opportunities.

Authors:  B J Fahey; S J Hsu; P D Wolf; R C Nelson; G E Trahey
Journal:  Phys Med Biol       Date:  2006-07-20       Impact factor: 3.609

4.  An investigation of the use of transmission ultrasound to measure acoustic attenuation changes in thermal therapy.

Authors:  Neeta Parmar; Michael C Kolios
Journal:  Med Biol Eng Comput       Date:  2006-06-10       Impact factor: 2.602

5.  Multiple-electrode radiofrequency ablation creates confluent areas of necrosis: in vivo porcine liver results.

Authors:  Paul F Laeseke; Lisa A Sampson; Dieter Haemmerich; Christopher L Brace; Jason P Fine; Tina M Frey; Thomas C Winter; Fred T Lee
Journal:  Radiology       Date:  2006-08-23       Impact factor: 11.105

6.  A new technique for localization of hepatic tumors that are poorly visible with CT fluoroscopy.

Authors:  Lionel Arrivé; Olivier Rosmorduc; Louisa Azizi; Laurence Monnier-Cholley; Maïté Lewin; Marc Beaussier; Jean-Michel Tubiana
Journal:  Eur Radiol       Date:  2006-04-19       Impact factor: 5.315

7.  Challenges and implementation of radiation-force imaging with an intracardiac ultrasound transducer.

Authors:  Stephen J Hsu; Brian J Fahey; Douglas M Dumont; Patrick D Wolf; Gregg E Trahey
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2007-05       Impact factor: 2.725

8.  Segmentation of elastographic images using a coarse-to-fine active contour model.

Authors:  Wu Liu; James A Zagzebski; Tomy Varghese; Charles R Dyer; Udomchai Techavipoo; Timothy J Hall
Journal:  Ultrasound Med Biol       Date:  2006-03       Impact factor: 2.998

9.  Stereotactically navigated percutaneous microwave ablation (MWA) compared to conventional MWA: a matched pair analysis.

Authors:  L P Beyer; L Lürken; N Verloh; M Haimerl; K Michalik; J Schaible; C Stroszczynski; P Wiggermann
Journal:  Int J Comput Assist Radiol Surg       Date:  2018-05-04       Impact factor: 2.924

10.  Three-dimensional sheaf of ultrasound planes reconstruction (SOUPR) of ablated volumes.

Authors:  Atul Ingle; Tomy Varghese
Journal:  IEEE Trans Med Imaging       Date:  2014-05-02       Impact factor: 10.048

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.