Literature DB >> 10947625

Electrostatic forces on the surface of metals as measured by atomic force microscopy.

E A Sprague1, J C Palmaz, C Simon, A Watson.   

Abstract

Electrostatic forces play an important role in modulating the interaction of plasma proteins and blood cellular components with the surface of the vascular endothelium. Based on the concept that electrostatic forces residing on the surface of metal intravascular prostheses, such as the stent, also are critical in influencing blood interactions with those surfaces and the vascular wall, these studies were designed to measure these forces on 4 metals using atomic force microscopy (AFM). AFM measurements performed in a low saline aqueous medium at physiological pH indicate a similar net electronegative surface charge level for gold and 316l stainless steel that is significantly higher than the level measured on an electropolished Nitinol surface. Heat oxidation of the Nitinol surface increased the overall electronegativity and created a more homogeneous surface charge distribution. This study demonstrates that AFM force measurements can be a valuable approach to understanding the electrostatic surface of metallic as well as other biomaterials that may be important in understanding how these surfaces influence vascular healing at intravascular interventional sites.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10947625     DOI: 10.1615/jlongtermeffmedimplants.v10.i12.100

Source DB:  PubMed          Journal:  J Long Term Eff Med Implants        ISSN: 1050-6934


  3 in total

1.  Stent thrombogenicity early in high-risk interventional settings is driven by stent design and deployment and protected by polymer-drug coatings.

Authors:  Kumaran Kolandaivelu; Rajesh Swaminathan; William J Gibson; Vijaya B Kolachalama; Kim-Lien Nguyen-Ehrenreich; Virginia L Giddings; Leslie Coleman; Gee K Wong; Elazer R Edelman
Journal:  Circulation       Date:  2011-03-21       Impact factor: 29.690

2.  Vascular response and intrastent thrombus in the early phase after drug-eluting versus bare-metal stent implantation in patients with ST-segment elevation myocardial infarction: An observational, single-center study.

Authors:  Nobuhiro Sato; Yoshiyasu Minami; Takao Shimohama; Ryo Kameda; Taiki Tojo; Junya Ako
Journal:  Health Sci Rep       Date:  2018-12-05

3.  Bring that pioneering spirit back! A 25-year perspective on the vascular stent.

Authors:  Julio C Palmaz
Journal:  Cardiovasc Intervent Radiol       Date:  2007-09-06       Impact factor: 2.740

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.