Literature DB >> 10947262

Quality assurance for a treatment planning system in scanned ion beam therapy.

O Jäkel1, G H Hartmann, C P Karger, P Heeg, J Rassow.   

Abstract

Conformal radiation therapy using dynamic beam delivery systems like scanned ion beams requires concise quality assurance procedures for the complete treatment planning process. For the heavy ion therapy facility at GSI, Darmstadt, a quality assurance program for the treatment planning system (TPS) has been developed. It covers the development and updating of software, data protection and safety, and the application of soft- and hardware. The tests also apply to the geometrical precision of imaging devices and the geometrical and dosimetrical verification of dose distributions in different phantoms. The quality assurance program addresses acceptance and constancy tests of the treatment planning program. Results of the acceptance tests served as a basis for its governmental approval. Two main results of the acceptance tests are representative for the overall performance of the system. (1) The geometrical uncertainty that could be achieved for the target point definition, setup accuracy, field contouring, and field alignment is typically 1.5 mm. The uncertainty for the setup verification using digitally reconstructed radiographs (DRR's) is limited to 2 mm. (2) The mean deviations between measured and planned dose values is 3% for standardized cases in a water phantom and up to 6% for more complicated treatment configurations.

Mesh:

Substances:

Year:  2000        PMID: 10947262     DOI: 10.1118/1.599025

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  3 in total

1.  Monitoring of patients treated with particle therapy using positron-emission-tomography (PET): the MIRANDA study.

Authors:  Stephanie E Combs; Julia Bauer; Daniel Unholtz; Christopher Kurz; Thomas Welzel; Daniel Habermehl; Thomas Haberer; Jürgen Debus; Katia Parodi
Journal:  BMC Cancer       Date:  2012-04-03       Impact factor: 4.430

Review 2.  Towards effective and efficient patient-specific quality assurance for spot scanning proton therapy.

Authors:  X Ronald Zhu; Yupeng Li; Dennis Mackin; Heng Li; Falk Poenisch; Andrew K Lee; Anita Mahajan; Steven J Frank; Michael T Gillin; Narayan Sahoo; Xiaodong Zhang
Journal:  Cancers (Basel)       Date:  2015-04-10       Impact factor: 6.639

3.  Methodology paper: a novel phantom setup for commissioning of scanned ion beam delivery and TPS.

Authors:  O Jäkel; B Ackermann; S Ecker; M Ellerbrock; P Heeg; K Henkner; M Winter
Journal:  Radiat Oncol       Date:  2019-05-09       Impact factor: 3.481

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.