Literature DB >> 10945945

Videoendoscopic thoracic aorta-to-femoral artery bypass in the pig.

A A Noel1, P Gloviczki, M M Young, K Karnicki, C Deschamps, C Moir.   

Abstract

BACKGROUND: The thoracoscopic approach to the aorta has the advantages of easy aortic dissection, excellent inflow, improved exposure in the thorax without insufflation, and ability to employ both laparoscopic and traditional instruments. Our aim was to develop a thoracoscopic technique for descending thoracic aorta-to-femoral artery bypass (TAFB) in the pig that results in acceptable short-term survival and graft patency.
MATERIALS AND METHODS: Thoracoscopic TAFB was performed in 11 pigs. Using two-lung ventilation, the animals were placed in a 45 degrees left lateral semidecubitus position. A fan lung retractor, two dissecting ports, intercostal artery loops, and camera were placed through five 10- to 20-mm thoracoscopic incisions. After aortic dissection, an 8-mm graft was passed through a retroperitoneal tunnel. Rumel tourniquets were used for aortic occlusion after placement of a shunt. End-to-side endoscopic anastomosis was completed with knots tied extracorporeally. The left femoral anastomosis was completed under direct vision. Duplex ultrasound of the graft was done on postoperative days 1, 3, and 7.
RESULTS: Thoracoscopic TAFB was completed in all animals. Mean aortic anastomosis time was 57 min (range, 34-145); and mean cross-clamp time, 74 min (range, 53-155). Mean operative time was 310 min; the first six operations lasted longer than the last five (338 min vs 276 min, P < 0.04). Average blood loss was 611 ml (range, 250-1300). Two animals died due to anesthetic complications. One (11%) of the nine surviving pigs died on day 2 due to bleeding. Complications were paraplegia in one (11%) and graft thrombosis in another (11%).
CONCLUSIONS: Videoendoscopic TAFB can be completed in pigs with acceptable short-term patency and survival. Further experience in thoracoscopic techniques can make TAFB a feasible and low-risk option for selected patients with aortoiliac occlusive disease. Copyright 2000 Academic Press.

Entities:  

Mesh:

Year:  2000        PMID: 10945945     DOI: 10.1006/jsre.2000.5933

Source DB:  PubMed          Journal:  J Surg Res        ISSN: 0022-4804            Impact factor:   2.192


  2 in total

1.  Performance measurements in endolaparoscopic infrarenal aortic graft implantation using computer-enhanced instrumentation: a laboratory model for training.

Authors:  Bernardo D Martinez; Catherine S Wiegand; Jose Mendez
Journal:  JSLS       Date:  2007 Jul-Sep       Impact factor: 2.172

2.  A porcine model for endolaparoscopic abdominal aortic repair and endoscopic training.

Authors:  Bernardo D Martinez; Christopher K Zarins; David A Daunt; Leslie A Coleman; Yamil Saenz; Thomas J Fogarty; George D Hermann; Camran R Nezhat; Eric K Olsen
Journal:  JSLS       Date:  2003 Apr-Jun       Impact factor: 2.172

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.