Literature DB >> 10942090

Peripheral CD4+/CD8+ T-lymphocyte counts estimated by an immunocapture method in the normal healthy south Indian adults and HIV seropositive individuals.

R Kannangai1, K J Prakash, S Ramalingam, O C Abraham, K P Mathews, M V Jesudason, G Sridharan.   

Abstract

BACKGROUND: Flow cytometry is the standard method for the estimation of CD4/CD8 counts, but the high initial investment for this instrument and costly reagents make it unaffordable to most of the centers in a developing country like India.
OBJECTIVES: To evaluate the feasibility of an alternate system for the estimation of CD4 and CD8 counts in normal south Indian adults and validate the usefulness of this assay to monitor the counts in HIV seropositive individuals. STUDY
DESIGN: Forty-six normal healthy adults and 68 HIV seropositive individuals both belonging to south Indian linguistic groups were enrolled in this cross-sectional study. The HIV seropositive individuals included 54 HIV-1, 9 HIV-2 and 5 HIV 1&2 infected individuals serologically confirmed by one of the commercial Immunoblot kits. The Capcellia CD4/CD8 whole blood assay, an immuno-capture ELISA based kit from Sanofi DIAGNOSTICS Pasteur, (France) was used with a few modifications in the procedure to measure the CD4 and CD8 counts.
RESULTS: The mean CD4 cell counts were 1048 (central 95 centile only), 746 and 424 for the normal healthy adults, asymptomatic HIV seropositives and symptomatic HIV patients, respectively, and the mean CD8 counts were 595, 889 and 732, respectively. Statistically significant differences were observed in the CD4 cell counts between HIV seronegative healthy adults and asymptomatic (P < 0.001) as well as asymptomatic and symptomatic (P < 0.05) HIV infected individuals. The mean CD4 counts of asymptomatic HIV-2 infected individuals was significantly higher than the counts of asymptomatic HIV-1 infected individuals (P < 0.05).
CONCLUSIONS: This is an user friendly test and can be an alternate to flow cytometry for the estimation of peripheral T-lymphocyte subsets in developing countries. The assay system has certain limitations inherent to ELISA techniques.

Entities:  

Mesh:

Year:  2000        PMID: 10942090     DOI: 10.1016/s1386-6532(00)00080-9

Source DB:  PubMed          Journal:  J Clin Virol        ISSN: 1386-6532            Impact factor:   3.168


  6 in total

1.  Efficacy of a fish protein hydrolysate in malnourished children.

Authors:  Knut Olav Nesse; A P Nagalakshmi; P Marimuthu; Mamta Singh
Journal:  Indian J Clin Biochem       Date:  2011-07-15

2.  Correlation of CD4(+) T-Cell counts estimated by an immunocapture technique (Capcellia) with viral loads in human immunodeficiency virus-seropositive individuals.

Authors:  R Kannangai; S Ramalingam; M V Jesudason; T S Vijayakumar; O C Abraham; A Zachariah; G Sridharan
Journal:  Clin Diagn Lab Immunol       Date:  2001-11

3.  Molecular confirmation of human immunodeficiency virus (HIV) type 2 in HIV-seropositive subjects in south India.

Authors:  R Kannangai; S Ramalingam; K J Prakash; O C Abraham; R George; R C Castillo; D H Schwartz; M V Jesudason; G Sridharan
Journal:  Clin Diagn Lab Immunol       Date:  2000-11

Review 4.  A review on peripheral blood CD4+ T lymphocyte counts in healthy adult Indians.

Authors:  Ashwini Shete; Madhuri Thakar; Philip Raj Abraham; Ramesh Paranjape
Journal:  Indian J Med Res       Date:  2010-12       Impact factor: 2.375

5.  A microchip CD4 counting method for HIV monitoring in resource-poor settings.

Authors:  William R Rodriguez; Nicolaos Christodoulides; Pierre N Floriano; Susan Graham; Sanghamitra Mohanty; Meredith Dixon; Mina Hsiang; Trevor Peter; Shabnam Zavahir; Ibou Thior; Dwight Romanovicz; Bruce Bernard; Adrian P Goodey; Bruce D Walker; John T McDevitt
Journal:  PLoS Med       Date:  2005-07-19       Impact factor: 11.069

6.  Establishment of reference range of CD4 T-lymphocyte in healthy Nepalese adults.

Authors:  Shravan Kumar Mishra; Lilee Shrestha; Roshan Pandit; Sundar Khadka; Bimal Shrestha; Subhash Dhital; Saroj Sharma; Mukunda Sharma; Raj Kumar Mahato; Geeta Shakya; Krishna Das Manandhar
Journal:  BMC Res Notes       Date:  2020-07-02
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.