Literature DB >> 10939402

A parallel miniature cylindrical ion trap array

.   

Abstract

A small mass spectrometer array is described in which each element is a cylindrical ion trap (CIT). The array contains four CITs, each having an inner radius of 2.5 mm, arranged in parallel and operated using a single electronics system under common conditions for trapping and mass analysis. By using an array of identically sized traps, higher ion capacity can be achieved than with a single miniature CIT, but the advantage of lower power and voltage requirements associated with the smaller ion trap is maintained. Overall signal intensity of the array of four traps is compared with that of a two-element CIT array to demonstrate the increased ion capacity of larger arrays. Resolution for m-dichlorobenzene is shown to be approximately 180 (full width at half-maximum), with no significant loss in resolution as a result of using multiple CITs. The detection of 5 x 10(-9) Torr partial pressure of krypton in argon with a signal-to-noise ratio of approximately 30 for the most abundant isotope is shown, demonstrating the applicability of the device for process gas monitoring. Also, a preliminary spectrum from a 10-CIT array with each element having an inner radius of 1.5 mm is reported.

Entities:  

Year:  2000        PMID: 10939402     DOI: 10.1021/ac000109p

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  10 in total

Review 1.  Miniature and Fieldable Mass Spectrometers: Recent Advances.

Authors:  Dalton T Snyder; Christopher J Pulliam; Zheng Ouyang; R Graham Cooks
Journal:  Anal Chem       Date:  2015-10-21       Impact factor: 6.986

2.  Simulations of ion trapping in a micrometer-sized cylindrical ion trap.

Authors:  Daniel E Austin; Dolores Cruz; Matthew G Blain
Journal:  J Am Soc Mass Spectrom       Date:  2006-01-25       Impact factor: 3.109

3.  Miniature toroidal radio frequency ion trap mass analyzer.

Authors:  Stephen A Lammert; Alan A Rockwood; Miao Wang; Milton L Lee; Edgar D Lee; Samuel E Tolley; James R Oliphant; Jeffrey L Jones; Randall W Waite
Journal:  J Am Soc Mass Spectrom       Date:  2006-05-12       Impact factor: 3.109

4.  Multiple mass analysis using an ion trap array (ITA) mass analyzer.

Authors:  Xiao Yu; Yanqiu Chu; Xing Ling; Zhengzhi Ding; Chongsheng Xu; Li Ding; Chuan-Fan Ding
Journal:  J Am Soc Mass Spectrom       Date:  2013-09       Impact factor: 3.109

5.  Novel ion traps using planar resistive electrodes: implications for miniaturized mass analyzers.

Authors:  Daniel E Austin; Ying Peng; Brett J Hansen; Ivan W Miller; Alan L Rockwood; Aaron R Hawkins; Samuel E Tolley
Journal:  J Am Soc Mass Spectrom       Date:  2008-04-16       Impact factor: 3.109

6.  Compressive mass analysis on quadrupole ion trap systems.

Authors:  Evan Xuguang Chen; Michael Gehm; Ryan Danell; Mitch Wells; Jeffrey T Glass; David Brady
Journal:  J Am Soc Mass Spectrom       Date:  2014-05-08       Impact factor: 3.109

7.  Experimental Observation of the Effects of Translational and Rotational Electrode Misalignment on a Planar Linear Ion Trap Mass Spectrometer.

Authors:  Yuan Tian; Trevor K Decker; Joshua S McClellan; Qinghao Wu; Abraham De la Cruz; Aaron R Hawkins; Daniel E Austin
Journal:  J Am Soc Mass Spectrom       Date:  2018-04-05       Impact factor: 3.109

8.  Improved Miniaturized Linear Ion Trap Mass Spectrometer Using Lithographically Patterned Plates and Tapered Ejection Slit.

Authors:  Yuan Tian; Trevor K Decker; Joshua S McClellan; Linsey Bennett; Ailin Li; Abraham De la Cruz; Derek Andrews; Stephen A Lammert; Aaron R Hawkins; Daniel E Austin
Journal:  J Am Soc Mass Spectrom       Date:  2017-08-23       Impact factor: 3.109

9.  Single Analyzer Precursor Ion Scans in a Linear Quadrupole Ion Trap Using Orthogonal Double Resonance Excitation.

Authors:  Dalton T Snyder; R Graham Cooks
Journal:  J Am Soc Mass Spectrom       Date:  2017-06-02       Impact factor: 3.109

10.  Ion sponge: a 3-dimentional array of quadrupole ion traps for trapping and mass-selectively processing ions in gas phase.

Authors:  Wei Xu; Linfan Li; Xiaoyu Zhou; Zheng Ouyang
Journal:  Anal Chem       Date:  2014-04-28       Impact factor: 6.986

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.