Y Murai1, T Hishinuma, N Suzuki, J Satoh, T Toyota, M Mizugaki.
Abstract
Liquid chromatography-tandem mass spectrometry (LC/MS-MS) was applied to the quantitative analysis of urinary 8-epi-prostaglandin F(2alpha) (8-epi-PGF(2alpha)) level. 8-Epi-PGF(2alpha) and its internal standard, [(2)H(4)]-8-epi-PGF(2alpha), were extracted from urine by using a solid phase extraction cartridge and loaded to LC/MS-MS in selected reaction monitoring (SRM) mode. The standard curve showed good linearity in the range of 40 pg to 10 ng (r = 0. 997). The accuracy of the added 8-epi-PGF(2alpha) ranged from 96.8 to 104.9% with a mean +/- SD of 99.5+/-2.5%. The average level +/- SD of urinary 8-epi-PGF(2alpha) in 13 healthy volunteers (five women and eight men, 31+/-7.4 years old) was 429.4+/-149.6 pg/mg creatinine. The level of seven patients with noninsulin dependent diabetes mellitus (two women and five men, 40+/-13.6 years old), 630.9+/-275.6 pg/mg creatinine, was statistically higher than that of healthy volunteers (P<0.05). This finding suggested that diabetics are in a highly oxidative condition. This simple and rapid LC/MS-MS method can be used to elucidate the pathophysiological feature of diabetes or for monitoring the curative effect.Entities:
Mesh:
Substances:
Year: 2000 PMID: 10938411 DOI: 10.1016/s0090-6980(00)00061-7
Source DB: PubMed Journal: Prostaglandins Other Lipid Mediat ISSN: 1098-8823 Impact factor: 3.072