Non-invasive myocardial iron assessment in thalassaemic patients. T2 relaxometry and magnetization transfer ratio measurements.

N Papanikolaou1, A Ghiatas, A Kattamis, C Ladis, N Kritikos, C Kattamis.   

Abstract

PURPOSE: To compare T2 relaxometry and magnetization transfer ratio (MTR) measurements of myocardial tissue in normal volunteers and thalassaemic patients for assessment of the myocardial iron levels.
MATERIAL AND METHODS: All examinations were done on a 1 T MR system using a multi-echo spin-echo sequence with 8 echoes for T2 measurements and a gradient echo sequence for MTR measurements. Diastolic cardiac triggering was used in both sequences. Ten patients and 10 normal subjects were included in the study. T2 and MTR measurements were correlated with serum ferritin levels.
RESULTS: Regression analysis between T2 and MTR measurements and ferritin demonstrated a reversed linear relationship, (r=-0.932, p<0.05) and (r= -0.824, p<0.05), respectively. Mean T2 relaxation time and mean MTR of the normal subjects (57.95+/-4.9 ms and 43.70+/-3.3%) was significantly higher than that of the thalassaemic patients (38.8+/-6.2 ms and 26.40+/-6.1%) (p<0.01), respectively.
CONCLUSION: MTR measurements can be used to complement T2 measurements for non-invasive myocardial iron assessment.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10937756     DOI: 10.1080/028418500127345442

Source DB:  PubMed          Journal:  Acta Radiol        ISSN: 0284-1851            Impact factor:   1.990


  6 in total

Review 1.  Cardiovascular magnetic resonance T2* for tissue iron assessment in the heart.

Authors:  Taigang He
Journal:  Quant Imaging Med Surg       Date:  2014-10

2.  Alternate ascending/descending directional navigation approach for imaging magnetization transfer asymmetry.

Authors:  Sung-Hong Park; Timothy Q Duong
Journal:  Magn Reson Med       Date:  2010-07-30       Impact factor: 4.668

3.  Free-breathing, motion-corrected, highly efficient whole heart T2 mapping at 3T with hybrid radial-cartesian trajectory.

Authors:  Hsin-Jung Yang; Behzad Sharif; Jianing Pang; Avinash Kali; Xiaoming Bi; Ivan Cokic; Debiao Li; Rohan Dharmakumar
Journal:  Magn Reson Med       Date:  2015-03-06       Impact factor: 4.668

4.  Direct saturation MRI: theory and application to imaging brain iron.

Authors:  Seth A Smith; Jeff W M Bulte; Peter C M van Zijl
Journal:  Magn Reson Med       Date:  2009-08       Impact factor: 4.668

5.  Bright-blood T(2)-weighted MRI has high diagnostic accuracy for myocardial hemorrhage in myocardial infarction: a preclinical validation study in swine.

Authors:  Alexander R Payne; Colin Berry; Peter Kellman; Rachel Anderson; Li-Yueh Hsu; Marcus Y Chen; Allan R McPhaden; Stuart Watkins; William Schenke; Victor Wright; Robert J Lederman; Anthony H Aletras; Andrew E Arai
Journal:  Circ Cardiovasc Imaging       Date:  2011-09-19       Impact factor: 7.792

6.  Multi-center transferability of a breath-hold T2 technique for myocardial iron assessment.

Authors:  Taigang He; Paul Kirk; David N Firmin; Wynnie M Lam; Winnie C W Chu; Wing-Yan Au; Godfrey C F Chan; Ru San Tan; Ivy Ng; Selen Biceroglu; Yesim Aydinok; Mark A Fogel; Alan R Cohen; Dudley J Pennell
Journal:  J Cardiovasc Magn Reson       Date:  2008-02-21       Impact factor: 5.364

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.