P O Alderson, R G Jost, A W Strauss, S Boonvisut, J Markham.
Abstract
A comparison of several reported methods for detection and quantitation of left-to-right shunts by radionuclides was performed in 50 children. Count ratio (C2/C1) techniques were compared with the exponential extrapolation and gamma function area ratio techniques. C2/C1 ratios accurately detected shunts and could reliably separate shunts from normals, but there was a high rate of false positives in children with valvular heart disease. The area ratio methods provided more accurate shunt quantitation and a better separation of patients with valvular heart disease than did the C2/C1 ratio. The gamma function method showed a higher correlation with oximetry than the exponential method, but the difference was not statistically significant. For accurate shunt quantitation and a reliable separation of patients with valvular heart disease from those with shunts, area ratio calculations are preferable to the C2/C1 ratio.Entities:
Mesh:
Substances:
Year: 1975 PMID: 1093759 DOI: 10.1161/01.cir.51.6.1136
Source DB: PubMed Journal: Circulation ISSN: 0009-7322 Impact factor: 29.690