Literature DB >> 10936122

Evaluation of myocardial injury following repeated internal atrial shocks by monitoring serum cardiac troponin I levels.

G Boriani1, M Biffi, V Cervi, G Bronzetti, G Magagnoli, R Zannoli, A Branzi.   

Abstract

INTRODUCTION: Electrical shocks delivered for atrial cardioversion (CV) may cause myocardial damage. The aim of this study was to assess the extent of myocardial injury caused by repeated intracardiac shocks delivered for low-energy internal atrial CV. METHODS AND
RESULTS: Thirty-five patients with chronic persistent atrial fibrillation (AF) of different etiologies underwent CV with delivery of synchronized biphasic shocks (3.0/3.0 ms) between two catheters positioned in the right atrium and the coronary sinus. Shocks were delivered according to a step-up protocol (50 V, 180 V, then steps of 40 to 56 V up to 500 V, if necessary). In 23 patients, AF was reinduced after baseline CV, and CV was repeated. Myocardial injury was monitored by measuring cardiac troponin I (cTnI) serum concentrations in blood samples taken at baseline and at 2, 4, 8, 12, and 24 h after the procedure, by means of an immunoenzymologic assay (normal values, < or =0.6 ng/mL). A mean (+/- SD) of 6.9 +/- 3.4 shocks per patient were delivered (range, 2 to 17). Shocks delivered in each patient had a maximal energy of 7.3 +/- 4.0 J (range, 1.7 to 15.7). In 20 patients (57%), no evidence of myocardial injury (cTnI level, < or = 0.6 ng/mL) was found. In 13 patients (37%), mildly elevated cTnI levels (range, 0.7 to 1.4 ng/mL) in samples taken 4 to 12 h after CV suggested minor myocardial injury. In two patients (6%), higher cTnI levels were found in samples taken 4 to 8 h after CV (peak, 1.7 and 2.4 ng/mL), indicating a necrotic damage. Patients with no cTnI elevation, with mild cTnI elevation, or with cTnI levels >or =1.5 ng/mL did not differ significantly with respect to the total number of shocks delivered, the mean amount of energy delivered, and the cumulative amount of energy delivered. No clinical complications were observed.
CONCLUSIONS: Following internal CV with the delivery of repeated shocks, minor elevations of cTnI serum levels could be detected in a significant proportion of patients, and this suggests subtle asymptomatic minor myocardial injury. The elevations of cTnI levels do not appear to be related to the number of shocks or to the amount of energy delivered.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10936122     DOI: 10.1378/chest.118.2.342

Source DB:  PubMed          Journal:  Chest        ISSN: 0012-3692            Impact factor:   9.410


  3 in total

1.  The association between defibrillation shock energy and acute cardiac damage in patients with implantable cardioverter defibrillators.

Authors:  Daisuke Ishigaki; Daisuke Kutsuzawa; Takanori Arimoto; Tadateru Iwayama; Naoaki Hashimoto; Yu Kumagai; Satoshi Nishiyama; Hiroki Takahashi; Tetsuro Shishido; Takuya Miyamoto; Joji Nitobe; Akio Fukui; Tetsu Watanabe; Isao Kubota
Journal:  J Arrhythm       Date:  2016-04-26

Review 2.  Optogenetics: Background, Methodological Advances and Potential Applications for Cardiovascular Research and Medicine.

Authors:  Jyotsna Joshi; Michael Rubart; Wuqiang Zhu
Journal:  Front Bioeng Biotechnol       Date:  2020-01-29

3.  When, how, and why should sinus rhythm be restored in patients with persistent atrial fibrillation?

Authors:  Kent Stephenson; Cory M Tschabrunn; Sujethra Vasu; Eric J Rashba
Journal:  Curr Treat Options Cardiovasc Med       Date:  2007-10
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.