Literature DB >> 10936007

Accuracy of fluoroscopic localization of the Crista terminalis documented by intracardiac echocardiography.

F E Marchlinski1, J F Ren, D Schwartzman, D J Callans, C D Gottlieb.   

Abstract

The crista terminalis is an important anatomic target for ablation of atrial arrhythmias. We determined the accuracy of catheter placement guided by fluoroscopy alone when directed to 24 sites along the crista terminalis in 6 patients. The sites selected included the most medial superior, most lateral superior, mid lateral, and most inferolateral sites along the crista terminalis in each patient. These sites were selected because of their recognized importance in sinus node and/or atrial tachycardia ablation and the importance of avoiding caval structures when targeting the most superior and/or inferior right atrium. The position of the catheter tip was documented using a catheter based ultrasound transducer in the right atrium or vena cava. The operator was blinded to the intracardiac echocardiographic (ICE) results until reviewing the images after the procedure in each patient. The catheter tip, guided by fluoroscopy alone, was identified by ICE to be within the right atrium and within 1cm of the crista terminalis at only 10 of the 24 sites (42%). Importantly, when targeting the most superior and inferior sites along the crista terminalis, the catheter tip, guided by fluoroscopy, was noted to be adjacent to the venous junction with the right atrium but actually located in the superior or inferior vena cava at 5 of the 18 such sites. The catheter was positioned appropriately (within 1 cm of the crista and within the right atrium) guided by fluoroscopy alone when targeting 1 of the 12 sites in the first 3 patients versus 9 of 12 sites in the last 3 patients, p<0.05. In conclusion, it appears that using fluoroscopic guidance alone: 1) localization of the crista terminalis is frequently inaccurate and 2) catheter positioning in the superior/inferior vena cava is commonly noted when targeting very superior and inferior sites along the crista terminalis. A learning curve, assisted by review of ICE recordings after each procedure, appears to improve the accuracy of catheter placement by fluoroscopy alone but still does not result in uniform success. ICE appears to facilitate and ensure accurate targeting of specific anatomic sites along the crista terminalis and thus may serve as an important adjunctive imaging technique in electrophysiology.

Entities:  

Mesh:

Year:  2000        PMID: 10936007     DOI: 10.1023/a:1009810718602

Source DB:  PubMed          Journal:  J Interv Card Electrophysiol        ISSN: 1383-875X            Impact factor:   1.900


  7 in total

1.  Narrowing of the superior vena cava-right atrium junction during radiofrequency catheter ablation for inappropriate sinus tachycardia: analysis with intracardiac echocardiography.

Authors:  D J Callans; J F Ren; D Schwartzman; C D Gottlieb; F A Chaudhry; F E Marchlinski
Journal:  J Am Coll Cardiol       Date:  1999-05       Impact factor: 24.094

2.  Imaging technique and clinical utility for electrophysiologic procedures of lower frequency (9 MHz) intracardiac echocardiography.

Authors:  J F Ren; D Schwartzman; D Callans; F E Marchlinski; C D Gottlieb; F A Chaudhry
Journal:  Am J Cardiol       Date:  1998-12-15       Impact factor: 2.778

3.  Radiofrequency catheter modification of the sinus node for "inappropriate" sinus tachycardia.

Authors:  R J Lee; J M Kalman; A P Fitzpatrick; L M Epstein; W G Fisher; J E Olgin; M D Lesh; M M Scheinman
Journal:  Circulation       Date:  1995-11-15       Impact factor: 29.690

4.  Radiofrequency catheter modification of sinus pacemaker function guided by intracardiac echocardiography.

Authors:  J M Kalman; R J Lee; W G Fisher; M C Chin; P Ursell; C A Stillson; M D Lesh; M M Scheinman
Journal:  Circulation       Date:  1995-11-15       Impact factor: 29.690

5.  Catheter ablation of sinoatrial node reentrant tachycardia.

Authors:  W E Sanders; R A Sorrentino; R A Greenfield; H Shenasa; M E Hamer; J M Wharton
Journal:  J Am Coll Cardiol       Date:  1994-03-15       Impact factor: 24.094

6.  Radiofrequency catheter ablation of atrial arrhythmias. Results and mechanisms.

Authors:  M D Lesh; G F Van Hare; L M Epstein; A P Fitzpatrick; M M Scheinman; R J Lee; M A Kwasman; H R Grogin; J C Griffin
Journal:  Circulation       Date:  1994-03       Impact factor: 29.690

7.  Radiofrequency catheter ablation of atrial tachycardias.

Authors:  H Poty; N Saoudi; M Haissaguerre; A Daou; J Clementy; B Letac
Journal:  Am Heart J       Date:  1996-03       Impact factor: 4.749

  7 in total
  1 in total

Review 1.  Intracardiac echocardiographic anatomy for the interventional electrophysiologist.

Authors:  Joseph B Morton; Jonathan M Kalman
Journal:  J Interv Card Electrophysiol       Date:  2005-08       Impact factor: 1.900

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.