Potential MR hazard to patients with metallic heart valves: the Lenz effect.

B Condon1, D M Hadley.   

Abstract

The Lenz effect on the motion of metal containing moving parts of artificial heart valves has not been considered to date. In this paper the basic theory is outlined and a simple model applied to estimate worst-case forces on such valves. The results indicate a potential for forces over 100 times greater than for the more widely recognized ferromagnetic interation. Resistive pressure effects comparable to cardiac pressure differences may occur for such valves in the mitral position even at fields as low as 1.5 T. The effect will increase linearly with field strength. Additional monitoring and perhaps even exclusion of such patients may be prudent, even at 1.5 T.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10931577     DOI: 10.1002/1522-2586(200007)12:1<171::aid-jmri19>3.0.co;2-w

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  6 in total

Review 1.  A Review of Numerical Simulation and Analytical Modeling for Medical Devices Safety in MRI.

Authors:  J Kabil; L Belguerras; S Trattnig; C Pasquier; J Felblinger; A Missoffe
Journal:  Yearb Med Inform       Date:  2016-11-10

2.  Follow-up and management of valvular heart disease patients with prosthetic valve: a clinical practice guideline for Indian scenario.

Authors:  Devendra Saksena; Yugal K Mishra; S Muralidharan; Vivek Kanhere; Pankaj Srivastava; C P Srivastava
Journal:  Indian J Thorac Cardiovasc Surg       Date:  2019-01-28

Review 3.  MRI in patients with cardiac devices.

Authors:  Edward T Martin; David A Sandler
Journal:  Curr Cardiol Rep       Date:  2007-03       Impact factor: 2.931

4.  Effects of heart valve prostheses on phase contrast flow measurements in Cardiovascular Magnetic Resonance - a phantom study.

Authors:  Johanna Richau; Matthias A Dieringer; Julius Traber; Florian von Knobelsdorff-Brenkenhoff; Andreas Greiser; Carsten Schwenke; Jeanette Schulz-Menger
Journal:  J Cardiovasc Magn Reson       Date:  2017-01-16       Impact factor: 5.364

Review 5.  Methods of estimation of mitral valve regurgitation for the cardiac surgeon.

Authors:  Efstratios E Apostolakis; Nikolaos G Baikoussis
Journal:  J Cardiothorac Surg       Date:  2009-07-15       Impact factor: 1.637

6.  Solenoidal Micromagnetic Stimulation Enables Activation of Axons With Specific Orientation.

Authors:  Laleh Golestanirad; John T Gale; Nauman F Manzoor; Hyun-Joo Park; Lyall Glait; Frederick Haer; James A Kaltenbach; Giorgio Bonmassar
Journal:  Front Physiol       Date:  2018-07-27       Impact factor: 4.566

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.