Literature DB >> 10930774

High-resolution diffusion imaging using phase-corrected segmented echo-planar imaging.

S Brockstedt1, J R Moore, C Thomsen, S Holtås, F Ståhlberg.   

Abstract

Diffusion magnetic resonance imaging (MRI) was performed with a high-resolution segmented echo-planar imaging technique, which provided images with substantially less susceptibility artifacts than images obtained with single-shot echo-planar imaging (EPI). Diffusion imaging performed with any multishot pulse sequence is inherently sensitive to motion artifacts and in order to reduce motion artifacts, the presented method utilizes navigator echo phase corrections, performed after a one-dimensional Fourier transform along the frequency-encoding direction. Navigator echo phases were fitted to a straight line prior to phase correction to avoid errors from internal motion. In vivo imaging was performed using electro cardiographic (ECG) triggering. Apparent diffusion coefficient (ADC) maps were calculated on a pixel-by-pixel basis using up to seven diffusion sensitivities, ranging from b = 0 to 1129 x 10(6) s/m(2).

Mesh:

Year:  2000        PMID: 10930774     DOI: 10.1016/s0730-725x(00)00159-4

Source DB:  PubMed          Journal:  Magn Reson Imaging        ISSN: 0730-725X            Impact factor:   2.546


  7 in total

1.  Reduced-distortion diffusion MRI of the craniovertebral junction.

Authors:  M Iima; A Yamamoto; V Brion; T Okada; M Kanagaki; K Togashi; D Le Bihan
Journal:  AJNR Am J Neuroradiol       Date:  2012-03-01       Impact factor: 3.825

2.  Tractography for arteriovenous malformations near the sensorimotor cortices.

Authors:  Kei Yamada; Osamu Kizu; Hirotoshi Ito; Takao Kubota; Wataru Akada; Mariko Goto; Akihiro Takada; Jyunya Konishi; Hiroyasu Sasajima; Katsuyoshi Mineura; Susumu Mori; Tsunehiko Nishimura
Journal:  AJNR Am J Neuroradiol       Date:  2005-03       Impact factor: 3.825

3.  PROPELLER EPI: an MRI technique suitable for diffusion tensor imaging at high field strength with reduced geometric distortions.

Authors:  Fu-Nien Wang; Teng-Yi Huang; Fa-Hsuan Lin; Tzu-Chao Chuang; Nan-Kuei Chen; Hsiao-Wen Chung; Cheng-Yu Chen; Kenneth K Kwong
Journal:  Magn Reson Med       Date:  2005-11       Impact factor: 4.668

4.  A tractography comparison between turboprop and spin-echo echo-planar diffusion tensor imaging.

Authors:  Minzhi Gui; Huiling Peng; John D Carew; Maciej S Lesniak; Konstantinos Arfanakis
Journal:  Neuroimage       Date:  2008-06-21       Impact factor: 6.556

Review 5.  State-of-the-art MRI techniques in neuroradiology: principles, pitfalls, and clinical applications.

Authors:  Magalie Viallon; Victor Cuvinciuc; Benedicte Delattre; Laura Merlini; Isabelle Barnaure-Nachbar; Seema Toso-Patel; Minerva Becker; Karl-Olof Lovblad; Sven Haller
Journal:  Neuroradiology       Date:  2015-04-10       Impact factor: 2.804

6.  Fast diffusion imaging with high angular resolution.

Authors:  Tzu-Cheng Chao; Jr-Yuan George Chiou; Stephan E Maier; Bruno Madore
Journal:  Magn Reson Med       Date:  2016-02-21       Impact factor: 4.668

7.  In vivo high angular resolution diffusion-weighted imaging of mouse brain at 16.4 Tesla.

Authors:  Othman I Alomair; Ian M Brereton; Maree T Smith; Graham J Galloway; Nyoman D Kurniawan
Journal:  PLoS One       Date:  2015-06-25       Impact factor: 3.240

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.