Literature DB >> 10930006

Sources of error in comparing functional magnetic resonance imaging and invasive electrophysiological recordings.

D L Hill1, A D Smith, A Simmons, C R Maurer, T C Cox, R Elwes, M Brammer, D J Hawkes, C E Polkey.   

Abstract

OBJECT: Several authors have recently reported studies in which they aim to validate functional magnetic resonance (fMR) imaging against the accepted gold standard of invasive electrophysiological monitoring. The authors have conducted a similar study, and in this paper they identify and quantify two characteristics of these data that can make such a comparison problematic.
METHODS: Eight patients in whom surgery for epilepsy was performed and five healthy volunteers underwent fMR imaging to localize the part of the sensorimotor cortex responsible for hand movement. In the patient group subdural electrode mats were subsequently implanted to identify eloquent regions of the brain and the epileptogenic zone. The fMR imaging data were processed to correct for motion during the study and then registered with a postimplantation computerized tomography (CT) scan on which the electrodes were visible. The motion during imaging in the two groups studied, and the deformation of the brain between the preoperative images and postoperative scans were measured. The patients who underwent epilepsy surgery moved significantly more during fMR imaging experiments than healthy volunteers performing the same motor task. This motion had a particularly increased out-of-plane component and was significantly more correlated with the stimulus than in the volunteers. This motion was especially increased when the patients were performing a task on the side affected by the lesion. The additional motion is hard to correct and substantially degrades the quality of the resulting fMR images, making it a much less reliable technique for use in these patients than in others. Also, the authors found that after electrode implantation, the brain surface can shift more than 10 mm relative to the skull compared with its preoperative location, substantially degrading the accuracy of the comparison of electrophysiological measurements made in the deformed brain and fMR studies obtained preoperatively.
CONCLUSIONS: These two findings indicate that studies of this sort are currently of limited use for validating fMR imaging and should be interpreted with care. Additional image analysis research is necessary to solve the problems caused by patients' motion and brain deformation.

Entities:  

Mesh:

Year:  2000        PMID: 10930006     DOI: 10.3171/jns.2000.93.2.0214

Source DB:  PubMed          Journal:  J Neurosurg        ISSN: 0022-3085            Impact factor:   5.115


  14 in total

1.  Metabolic and electrophysiological validation of functional MRI.

Authors:  T Krings; M Schreckenberger; V Rohde; H Foltys; U Spetzger; O Sabri; M H Reinges; S Kemeny; P T Meyer; W Möller-Hartmann; M Korinth; J M Gilsbach; U Buell; A Thron
Journal:  J Neurol Neurosurg Psychiatry       Date:  2001-12       Impact factor: 10.154

2.  Visualization of subdural strip and grid electrodes using curvilinear reformatting of 3D MR imaging data sets.

Authors:  Andreas H-J Schulze-Bonhage; Hans J Huppertz; Roch M Comeau; Jürgen B Honegger; Joachim M Spreer; Josef K Zentner
Journal:  AJNR Am J Neuroradiol       Date:  2002-03       Impact factor: 3.825

3.  Quantitative comparison of functional MRI and direct electrocortical stimulation for functional mapping.

Authors:  S Larsen; R Kikinis; I-F Talos; D Weinstein; W Wells; A Golby
Journal:  Int J Med Robot       Date:  2007-09       Impact factor: 2.547

Review 4.  Awake surgery between art and science. Part I: clinical and operative settings.

Authors:  Andrea Talacchi; Barbara Santini; Francesca Casagrande; Franco Alessandrini; Giada Zoccatelli; Giovanna M Squintani
Journal:  Funct Neurol       Date:  2013 Jul-Sep

5.  Presurgical motor, somatosensory and language fMRI: Technical feasibility and limitations in 491 patients over 13 years.

Authors:  Anthony J Tyndall; Julia Reinhardt; Volker Tronnier; Luigi Mariani; Christoph Stippich
Journal:  Eur Radiol       Date:  2016-05-19       Impact factor: 5.315

6.  Individualized localization and cortical surface-based registration of intracranial electrodes.

Authors:  Andrew R Dykstra; Alexander M Chan; Brian T Quinn; Rodrigo Zepeda; Corey J Keller; Justine Cormier; Joseph R Madsen; Emad N Eskandar; Sydney S Cash
Journal:  Neuroimage       Date:  2011-11-28       Impact factor: 6.556

7.  Perimetric visual field and functional MRI correlation: implications for image-guided surgery in occipital brain tumours.

Authors:  F E Roux; D Ibarrola; J A Lotterie; F Chollet; I Berry
Journal:  J Neurol Neurosurg Psychiatry       Date:  2001-10       Impact factor: 10.154

Review 8.  Functional magnetic resonance imaging for neurosurgical planning in neurooncology.

Authors:  Erik-Jan Vlieger; Charles B Majoie; Sieger Leenstra; Gerard J Den Heeten
Journal:  Eur Radiol       Date:  2004-05-18       Impact factor: 5.315

9.  Pre-motor versus motor cerebral cortex neuromodulation for chronic neuropathic pain.

Authors:  Igor Lavrov; Timur Latypov; Elvira Mukhametova; Brian Lundstrom; Paola Sandroni; Kendall Lee; Bryan Klassen; Matt Stead
Journal:  Sci Rep       Date:  2021-06-16       Impact factor: 4.379

10.  Intraoperative electrical stimulation mapping as an aid for surgery of intracranial lesions involving motor areas in children.

Authors:  Francesco Signorelli; J Guyotat; C Mottolese; F Schneider; G D'Acunzi; J Isnard
Journal:  Childs Nerv Syst       Date:  2004-05-07       Impact factor: 1.475

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.