Literature DB >> 10930005

Computer-assisted neurosurgery by using a noninvasive vacuum-affixed dental cast that acts as a reference base: another step toward a unified approach in the treatment of brain tumors.

R J Bale1, J Burtscher, W Eisner, A A Obwegeser, M Rieger, R A Sweeney, A Dessl, S M Giacomuzzi, K Twerdy, W Jaschke.   

Abstract

OBJECT: The purpose of the study was to evaluate the use of the Vogele-Bale-Hohner (VBH) mouthpiece, which is attached to the patient's upper jaw by negative pressure, for patient-image registration and for tracking the patient's head during image-guided neurosurgery.
METHODS: A dynamic reference frame (DRF) is reproducibly mounted on the mouthpiece. Reference points, optimally distributed and attached to the mouthpiece, are used for registration in the patient's absence on the day before surgery. In the operating room, the mouthpiece and DRF are precisely repositioned using a vacuum, and the patient's anatomical structures are automatically registered to corresponding ones on the image. Experimental studies and clinical experiences in 10 patients confirmed repeated (rigid body) localization accuracy in the range of 0 to 2 mm, throughout the entire surgery despite movements by the patient.
CONCLUSIONS: Because of its noninvasive, rigid, reliable, and reproducible connection to the patient's head, the VBH vacuum-affixed mouthpiece grants the registration device an accuracy comparable to invasive fiducial markers.

Entities:  

Mesh:

Year:  2000        PMID: 10930005     DOI: 10.3171/jns.2000.93.2.0208

Source DB:  PubMed          Journal:  J Neurosurg        ISSN: 0022-3085            Impact factor:   5.115


  6 in total

1.  On "Evaluation of the Contribution of CAS in Combination with the Subcranial/Subfrontal Approach in Anterior Skull Base Surgery" (Skull Base 2001;11:59-76).

Authors:  Walter F Thumfart; Wolfgang Freysinger
Journal:  Skull Base       Date:  2002-02

2.  A projected landmark method for reduction of registration error in image-guided surgery systems.

Authors:  Nasim Dadashi Serej; Alireza Ahmadian; Saeed Mohagheghi; Seyed Musa Sadrehosseini
Journal:  Int J Comput Assist Radiol Surg       Date:  2014-05-28       Impact factor: 2.924

3.  Image-guided surgery and medical robotics in the cranial area.

Authors:  G Widmann
Journal:  Biomed Imaging Interv J       Date:  2007-01-01

4.  Study on the clinical application of pulsed DC magnetic technology for tracking of intraoperative head motion during frameless stereotaxy.

Authors:  Olaf Suess; Silke Suess; Sven Mularski; Björn Kühn; Thomas Picht; Stefanie Hammersen; Rüdiger Stendel; Mario Brock; Theodoros Kombos
Journal:  Head Face Med       Date:  2006-04-26       Impact factor: 2.151

5.  Standards of anesthesiology practice during neuroradiological interventions.

Authors:  Wolfgang Lederer; Astrid Grams; Raimund Helbok; Martina Stichlberger; Reto Bale; Franz J Wiedermann
Journal:  Open Med (Wars)       Date:  2016-10-21

6.  Registration-free workflow for electromagnetic and optical navigation in orbital and craniofacial surgery.

Authors:  R Schreurs; F Baan; C Klop; L Dubois; L F M Beenen; P E M H Habets; A G Becking; T J J Maal
Journal:  Sci Rep       Date:  2021-09-10       Impact factor: 4.379

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.