Literature DB >> 10929977

Open drops in ophthalmology offices: expiration and contamination.

I F Wessels1, P Bekendam, W S Calvin, G J Zimmerman.   

Abstract

OBJECTIVE: To determine the relationship between eye drop use and contamination rate in ophthalmology offices.
DESIGN: Following permission request, open bottles were examined and the nozzle tip and one drop of content was cultured on solid media. OUTCOME MEASURES: Drug category, volume, weight compared to full, clean legible label, expiration date; 2 or more bacterial colonies along the inoculation site.
RESULTS: In 18 offices, of 1,485 open bottles (mean 12.2, range 4 to 23 per lane) on average 19.8% (range 0% to 88%) were expired (16.2 of 82.5 bottles per office). The frequency of occurrence (%) and expiration (%E) were 40.3% cycloplegics (19.4%E); 16.4% glaucoma (33.7%E); 10.8% anesthetics (8.8%E); and 4% steroids (8.8%E; or 42.2%E including one outlier). Most likely expired were glaucoma (P < 0.001); small 2-3 ml (P < 0.02), nearly empty (P < 0.05), or dirty (P < 0.001) bottles. Only one (5 ml cyclopentolate, not expired) grew a Micrococcus (0.07%).
CONCLUSIONS: Drops in ophthalmology offices may be expired but are not contaminated.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10929977

Source DB:  PubMed          Journal:  Ophthalmic Surg Lasers        ISSN: 1082-3069


  4 in total

1.  A simple stratification & storage system for samples and supplies.

Authors:  Sapna Lohiya
Journal:  J Natl Med Assoc       Date:  2006-03       Impact factor: 1.798

2.  Microbial contamination of multi-use ophthalmic solutions in Kenya.

Authors:  M M Nentwich; K H M Kollmann; J Meshack; D R Ilako; U C Schaller
Journal:  Br J Ophthalmol       Date:  2007-05-02       Impact factor: 4.638

3.  Microbial contamination of glaucoma eyedrops used by patients compared with ocular medications used in the hospital.

Authors:  Barbara Teuchner; Julia Wagner; Nikolaos E Bechrakis; Dorothea Orth-Höller; Markus Nagl
Journal:  Medicine (Baltimore)       Date:  2015-02       Impact factor: 1.889

4.  Microbial Cross-contamination in Multidose Eyedrops: The Impact of Instillation Angle and Bottle Geometry.

Authors:  Alexandre Xavier da Costa; Maria Cecilia Zorat Yu; Denise de Freitas; Priscila Cardoso Cristovam; Lauren C LaMonica; Vagner Rogerio Dos Santos; José Alvaro Pereira Gomes
Journal:  Transl Vis Sci Technol       Date:  2020-06-05       Impact factor: 3.283

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.