Incidence of atrial flutter and atrial fibrillation in patients with implanted physiological pacemakers.

T Ishikawa1, S Sumita, M Kikuchi, T Nakagawa, M Kosuge, N Kuji, K Kimura, O Tochikubo, T Usui, S Umemura.   

Abstract

Atrial flutter (AF) is a troublesome arrhythmia for patients with an implanted pacemaker. Although it has recently become possible to eliminate AF by radiofrequency catheter ablation (RF-CA), the incidence of AF before and after pacemaker implantation has not been clarified. The present study was conducted with 123 consecutive patients (69.3+/-11.6 (SD) years old) implanted with pacemakers, excluding patients who had chronic atrial fibrillation (AFib) when the pacemaker was implanted; 69 patients with atrioventricular (AV) block and 54 patients with sick sinus syndrome (including 29 patients with bradycardia-tachycardia syndrome). All patients were implanted with physiological pacemakers. The follow-up period was 4.7+/-1.9 years. In 11 of the 123 patients (8.9%), AF was observed before pacemaker implantation and the incidence was significantly higher in patients with sick sinus syndrome than in those with AV block (16.7 vs 2.9%, p<0.01). Nine of the 29 patients with bradycardia-tachycardia syndrome (31%) had AF. After physiological pacemaker implantation, AF recurred in 9 of the 11 patients, and AF was newly observed in 1 patient. Thus, 10 of the 123 patients (8.1%) had AF after physiological pacemaker implantation. Recurrence of AF was not suppressed by physiological pacing. Thirty of the 123 patients had AFib before implantation of a pacemaker and its occurrence was reduced by physiological pacing (from 24.4% to 12.2%, p<0.05). The incidence of AFib in patients with AF was significantly higher than in those without AF (90.0 vs 5.3%, p<0.001). In conclusion, the recurrence of AF is not prevented by physiological pacing and is closely related to the occurrence of AFib. RF-CA should be considered in patients who have AF before pacemaker implantation.

Entities:  

Mesh:

Year:  2000        PMID: 10929778     DOI: 10.1253/jcj.64.505

Source DB:  PubMed          Journal:  Jpn Circ J        ISSN: 0047-1828


  3 in total

1.  A re-analysis of our current understanding of isthmus-dependent atrial flutter: some gaps, some hypotheses.

Authors:  A Nabar
Journal:  Indian Pacing Electrophysiol J       Date:  2001-10-01

2.  Efficacy of automatic mode switching in DDDR mode pacemakers: the most 2 study.

Authors:  Maurizio Santomauro; Luca Ottaviano; Alessio Borrelli; Gennaro Galasso; Carlo Duilio; Nicola Monteforte; Luigi Padeletti; Annibale Sandro Montenero; Peter Andrew; Massimo Chiariello
Journal:  J Interv Card Electrophysiol       Date:  2008-01-30       Impact factor: 1.900

3.  Assessment of ventricular pacing in the setting of an institutional improvement program: insights into physiological pacing.

Authors:  Antoine Kossaify; Sylvana Zoghbi; Paul Milliez
Journal:  Clin Med Insights Cardiol       Date:  2012-03-08
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.