Literature DB >> 10927160

MR contrast media for myocardial viability, microvascular integrity and perfusion.

M Saeed1, M F Wendland, N Watzinger, H Akbari, C B Higgins.   

Abstract

Cardiovascular imaging requires an appreciation of rapidly evolving MR imaging sequences as well as careful utilization of intravascular, extracellular and intracellular MR contrast media. At the present time, clinical studies are restricted to the use of extracellular MR contrast media. MR imaging has the potential to noninvasively measure multiple parameters of the cardiovascular system in a single imaging session. Recent advances in fast and ultrafast MR imaging have considerably enhanced the capability of this technique, beyond the assessment of left ventricular wall motion and morphology into visualization of the coronary arteries and measurement of blood flow. During the course of the last several years, multiple strategies for imaging viable myocardium have been developed and validated using MR contrast media. Contrast enhanced dynamic MR imaging provides information regarding microvascular integrity and perfusion. Because these information can be provided noninvasively by MR imaging, repeated measurements can be performed in longitudinal studies to monitor the progression or regression of myocardial injury. Similar studies are needed to examine the effects of newly developed cardioprotective therapeutics. Development of suitable intravascular MR contrast medium may be essential for visualization of the coronary arteries and interventional therapies. MR imaging may emerge as one-stop-shop for evaluating the heart and coronary system. This capability will make MR imaging cost-effective in the first decade of this millennium.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10927160     DOI: 10.1016/s0720-048x(00)00198-4

Source DB:  PubMed          Journal:  Eur J Radiol        ISSN: 0720-048X            Impact factor:   3.528


  9 in total

Review 1.  Contrast agents and cardiac MR imaging of myocardial ischemia: from bench to bedside.

Authors:  Pierre Croisille; Didier Revel; Maythem Saeed
Journal:  Eur Radiol       Date:  2006-04-22       Impact factor: 5.315

Review 2.  Magnetic resonance approaches and recent advances in myocardial perfusion imaging.

Authors:  Daniel C Lee; Francis J Klocke
Journal:  Curr Cardiol Rep       Date:  2006-02       Impact factor: 2.931

3.  Rapid multislice T1 mapping of mouse myocardium: Application to quantification of manganese uptake in α-Dystrobrevin knockout mice.

Authors:  Kai Jiang; Wen Li; Wei Li; Sen Jiao; Laurie Castel; David R Van Wagoner; Xin Yu
Journal:  Magn Reson Med       Date:  2014-11-18       Impact factor: 4.668

Review 4.  MRI of the left atrium: predicting clinical outcomes in patients with atrial fibrillation.

Authors:  Marcos Daccarett; Chris J McGann; Nazem W Akoum; Rob S MacLeod; Nassir F Marrouche
Journal:  Expert Rev Cardiovasc Ther       Date:  2011-01

Review 5.  MRI in guiding and assessing intramyocardial therapy.

Authors:  M Saeed; D Saloner; O Weber; A Martin; C Henk; C Higgins
Journal:  Eur Radiol       Date:  2005-01-29       Impact factor: 5.315

6.  Rapid T1 mapping of mouse myocardium with saturation recovery Look-Locker method.

Authors:  Wen Li; Mark Griswold; Xin Yu
Journal:  Magn Reson Med       Date:  2010-11       Impact factor: 4.668

Review 7.  Assessment of myocardial ischemia and viability using cardiac magnetic resonance.

Authors:  Javier Sanz; Teresa Rius; Paola Kuschnir; Rafael Salguero Bodes; Michael Poon
Journal:  Curr Cardiol Rep       Date:  2004-01       Impact factor: 2.931

Review 8.  Contrast-enhanced cardiac MR imaging.

Authors:  G Schneider; P Fries; F Ahlhelm; I Kindermann; B Kramann; M Böhm
Journal:  Eur Radiol       Date:  2003-11       Impact factor: 7.034

9.  Preliminary assessment of cardiac short term safety and efficacy of manganese chloride for cardiovascular magnetic resonance in humans.

Authors:  Juliano L Fernandes; Pippa Storey; Jose Alvaro da Silva; Gabriel S de Figueiredo; Jose M Kalaf; Otavio R Coelho
Journal:  J Cardiovasc Magn Reson       Date:  2011-01-14       Impact factor: 5.364

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.