Literature DB >> 10926897

An IgM lambda antibody to Escherichia coli produces false-positive results in multiple immunometric assays.

M Covinsky1, O Laterza, J D Pfeifer, T Farkas-Szallasi, M G Scott.   

Abstract

BACKGROUND: Interferences in immunometric assays as a result of human anti-immunoglobulin antibodies frequently have been described in the literature. The etiology of these interfering antibodies is usually not known but has been associated with rheumatoid factors in some assays. It is known that microorganisms in experimental settings can induce anti-immunoglobulin antibodies.
METHODS: Following Escherichia coli septicemia, a 56-year-old male patient had increased immunoassay results for cardiac troponin I, thyrotropin, human chorionic gonadotropin, alpha-fetoprotein, and CA-125 that were consistent with myocardial infarction, hyperthyroidism, and pregnancy, and suggestive of an occult neoplasm such as hepatic or ovarian cancer. None of these diagnoses were consistent with the rest of his medical exam. In addition, the patient had a restricted IgM lambda paraprotein by immunofixation. Plasma from the patient was incubated with Sepharose-conjugated protein A, irrelevant murine monoclonal antibodies, and formalin-killed E. coli organisms from his infection to determine whether these immunoassay values were falsely increased.
RESULTS: Incubation of the patient's plasma with irrelevant murine monoclonal antibodies or the E. coli organism produced normal immunoassay values and removed the IgM lambda paraprotein.
CONCLUSIONS: The patient produced a very restricted IgM lambda antibody response to the E. coli infection that had anti-immunoglobulin activity and caused falsely increased values in numerous immunometric assays. Microorganism-induced anti-immunoglobulin antibodies are discussed in the context of this patient.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10926897

Source DB:  PubMed          Journal:  Clin Chem        ISSN: 0009-9147            Impact factor:   8.327


  6 in total

1.  Wrong biochemistry results.

Authors:  A A Ismail; J H Barth
Journal:  BMJ       Date:  2001-09-29

2.  On the diagnosis of subclinical hypothyroidism.

Authors:  Adel A A Ismail
Journal:  Br J Gen Pract       Date:  2007-12       Impact factor: 5.386

3.  Interferences in immunoassay.

Authors:  Jill Tate; Greg Ward
Journal:  Clin Biochem Rev       Date:  2004-05

4.  hCG production by mucinous adenocarcinoma of the ovary in a reproductive aged woman.

Authors:  Vincent Wagner; Heather Winn; Andreea Newtson; David Bender; Megan McDonald
Journal:  Gynecol Oncol Rep       Date:  2018-10-31

5.  Normocalcemia but still elevated parathyroid hormone levels after parathyroidectomy.

Authors:  Rick H A van der Doelen; Paul Nijhuis; Robert van der Velde; Marcel J W Janssen
Journal:  Clin Case Rep       Date:  2018-06-25

Review 6.  Hormone Immunoassay Interference: A 2021 Update.

Authors:  Khaldoun Ghazal; Severine Brabant; Dominique Prie; Marie-Liesse Piketty
Journal:  Ann Lab Med       Date:  2022-01-01       Impact factor: 3.464

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.