Literature DB >> 10925649

[Transplant fixation by anterior cruciate ligament reconstruction. Metal vs. bioabsorbable polyglyconate interference screw. A prospective randomized study of 40 patients].

W Hackl1, C Fink, K P Benedetto, C Hoser.   

Abstract

To overcome some of the potential problems (e.g. hardware removal during revision surgery) of metal interference screws used for patellar tendon anterior cruciate ligament reconstruction, bioabsorbable screws have recently been introduced. Forty patients who underwent endoscopic ACL reconstruction using patella tendon autograft were included in the study, they were randomized intraoperatively to either Group A (femoral bone block fixation: polyglyconate screw; tibial: metal screw) or Group B (both bone blocks fixed with metal interference screws). The patients were evaluated clinically preoperatively as well as 6 weeks, 3 months 12 months and 24 months post op. Lysholm Score at 24 months was 98.1 +/- 2.3 for Group A and 97.7 +/- 3.0 for Group B. Tegner Score was 7.4 +/- 1.1 for Group A and 7.5 +/- 0.8 for Group B. Two years post op overall IKDC-Score for group A was 5.6% normal, 88.8% nearly normal and 5.6% abnormal. The result for group B was 11.1%, 77.8% and 11.1%, respectively. KT-1000 (at 89 N) at two years revealed a side to side difference of 1.5 +/- 0.3 mm (Group A) and 1.6 +/- 0.7 (Group B). The results of the two groups did not show significant differences at any stage of follow up. In our study polyglyconate interference screw fixation for patellar tendon grafts has not found to be associated with increased clinical complications. It provided equivalent fixation and clinical results compared to metal screws.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10925649     DOI: 10.1007/s001130050567

Source DB:  PubMed          Journal:  Unfallchirurg        ISSN: 0177-5537            Impact factor:   1.000


  10 in total

1.  [ACL reconstruction with bone-patellar tendon-bone graft and proximal fixation with the EndoButton: a 2- to 5-year follow-up].

Authors:  K Tecklenburg; C Hoser; R Sailer; J Oberladstätter; C Fink
Journal:  Unfallchirurg       Date:  2005-09       Impact factor: 1.000

2.  Modified Prusik knot versus whipstitch technique for soft tissue fixation in anterior cruciate ligament reconstruction: a biomechanical analysis.

Authors:  Dietmar Krappinger; Franz Sebastian Kralinger; Rene El Attal; Wolfgang Hackl; Christian Haid
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2006-08-15       Impact factor: 4.342

3.  Meta-analysis comparing bioabsorbable versus metal interference screw for adverse and clinical outcomes in anterior cruciate ligament reconstruction.

Authors:  Pat Laupattarakasem; Malinee Laopaiboon; Weerachai Kosuwon; Wiroon Laupattarakasem
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-12-14       Impact factor: 4.342

4.  Biomechanical characteristics of bioabsorbable magnesium-based (MgYREZr-alloy) interference screws with different threads.

Authors:  Marco Ezechieli; Max Ettinger; Carolin König; Andreas Weizbauer; Patrick Helmecke; Robert Schavan; Arne Lucas; Henning Windhagen; Christoph Becher
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-09-24       Impact factor: 4.342

Review 5.  Comparison of Bioabsorbable and Metallic Interference Screws for Graft Fixation During ACL Reconstruction: A Meta-analysis of Randomized Controlled Trials.

Authors:  Baoyun Xu; Yuling Yin; Yanling Zhu; Yu Yin; Weili Fu
Journal:  Orthop J Sports Med       Date:  2021-08-18

Review 6.  Bioabsorbable versus metallic interference screws for graft fixation in anterior cruciate ligament reconstruction.

Authors:  Pedro Debieux; Carlos E S Franciozi; Mário Lenza; Marcel Jun Tamaoki; Robert A Magnussen; Flávio Faloppa; João Carlos Belloti
Journal:  Cochrane Database Syst Rev       Date:  2016-07-24

7.  Fixation strength of a novel bioabsorbable expansion bolt for patellar tendon bone graft fixation: an experimental study in calf tibial bone.

Authors:  Stefan Piltz; Patrick Strunk; Ludger Meyer; Wolfgang Plitz; Guenter Lob
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2004-03-24       Impact factor: 4.342

8.  Severe cartilage damage by broken poly-L-lactic acid (PLLA) interference screw after ACL reconstruction.

Authors:  Burkhard Lembeck; Nikolaus Wülker
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2004-11-11       Impact factor: 4.342

9.  Comparison of femoral fixation methods for anterior cruciate ligament reconstruction with patellar tendon graft: a mechanical analysis in porcine knees.

Authors:  Giuseppe Milano; Pier Damiano Mulas; Fabio Ziranu; Laura Deriu; Carlo Fabbriciani
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2007-02-13       Impact factor: 4.114

10.  A prospective randomized study of ACL-reconstructions using bone-patellar tendon-bone grafts fixed with bioabsorbable or metal interference screws.

Authors:  Jon Olav Drogset; Lene Granrud Straume; Ingrid Bjørkmo; Gunnar Myhr
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-01-14       Impact factor: 4.342

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.