Literature DB >> 10925224

Single-clamp technique for aneurysms of the descending thoracic aorta: report of 132 consecutive cases.

D A Cooley1, A Golino, O H Frazier.   

Abstract

OBJECTIVE: To determine the efficacy of a single-clamp technique in preventing spinal cord ischemia during repair of aneurysms of the descending thoracic aorta. PATIENTS AND METHODS: From January 1989 to May 1999, 132 consecutive patients (91 men and 41 women, aged 31-86 years), with aneurysms of the descending thoracic aorta underwent repair using a single-clamp technique and temporary partial distal exsanguination. The diseased aortic segment was replaced with a Dacron graft. Blood was re-infused from an auto-transfusion device, and the segmental vessels were over-sewn but not implanted into the graft.
RESULTS: The average aortic cross-clamp time was 26.4 min (range, 11-67 min) for the overall group and 37.4 min for patients who had spinal cord complications. An average of 2066 ml of blood was auto-transfused (range, 450-6100 ml). During the first 30 postoperative days, 17 patients (12.9 %) died. Eleven patients (8.3%) had spinal cord dysfunction, six patients (4.5%) had lower-extremity paraparesis, and five patients (3.8%) had paraplegia. Nine patients (6.8%) had renal failure necessitating hemodialysis. Other complications included bleeding in 15 cases (11.4%), respiratory failure in 12 cases (9.1%), wound-related sequelae in five cases (3.8%), distal embolism in five cases (3.8%), and bowel ischemia in two cases (1.5%).
CONCLUSION: The single-clamp technique yielded an acceptable complication rate, and the mortality was comparable to that seen after the use of more complex methods. For satisfactory results, the cross-clamp time should not exceed 30 min.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10925224     DOI: 10.1016/s1010-7940(00)00499-1

Source DB:  PubMed          Journal:  Eur J Cardiothorac Surg        ISSN: 1010-7940            Impact factor:   4.191


  3 in total

1.  Endovascular exclusion of a thoracoabdominal aortic aneurysm after retrograde visceral artery revascularization.

Authors:  Igor D Gregoric; Kamal Gupta; Michael J Jacobs; Gregor Poglajen; Nina Suvorov; Kathy G Dougherty; Zvonimir Krajcer
Journal:  Tex Heart Inst J       Date:  2005

2.  Outcomes of single-stage total arch replacement via clamshell incision.

Authors:  Hiroto Iwasaki; Hisashi Satoh; Toru Ishizaka; Hikaru Matsuda
Journal:  J Cardiothorac Surg       Date:  2011-09-20       Impact factor: 1.637

3.  The application of modular multifunctional left heart bypass circuit system integrated with ultrafiltration in thoracoabdominal aortic aneurysm repair.

Authors:  Lingjin Huang; Xuliang Chen; Qinghua Hu; Fanyan Luo; Jiajia Hu; Lian Duan; E Wang; Zhi Ye; Chengliang Zhang
Journal:  Front Cardiovasc Med       Date:  2022-09-21
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.