Literature DB >> 10924300

Atrial pacing for suppression of early reinitiation of atrial fibrillation after successful internal cardioversion.

H F Tse1, C P Lau, G M Ayers.   

Abstract

AIMS: To evaluate the efficacy of atrial pacing in the suppression of early reinitiation of atrial fibrillation after successful internal cardioversion. METHODS AND
RESULTS: The efficacy of atrial pacing in suppressing early reinitiation of atrial fibrillation was studied in 12 of 45 (29%) patients with early reinitiation of atrial fibrillation after successful cardioversion. These patients were randomized to undergo either repeated defibrillation alone or repeated defibrillation followed by high right atrial pacing at 500 ms in a crossover fashion. In patients with persistent early reinitiation of atrial fibrillation despite atrial pacing at 500 ms and repeated defibrillation, atrial pacing at 300 ms was tested. Lastly, if early reinitiation of atrial fibrillation persisted, administration of intravenous sotalol (1.5 mg. kg(-1)) was tested. Atrial pacing at 500 ms after defibrillation prevented early reinitiation of atrial fibrillation in five of 12 (42%) patients, and was significantly more effective than repeated defibrillation (0/9 patients, 0%, P<0.05). During atrial pacing at 500 ms, the density of atrial premature depolarizations (APDs) was significantly decreased (2.4+/-2.4 APDs. min(-1)vs 16.4+/-9.8 APDs. min(-1), P<0. 05) and the coupling interval of atrial premature depolarization was significantly increased (420+/-32 ms vs 398+/-19 ms, P<0.05) as compared to no pacing. In the remaining seven (58%) patients, atrial pacing at 500 ms failed to prevent early reinitiation of atrial fibrillation, but significantly decreased the density of atrial premature depolarization (3.4+/-2.4 APDs. min(-1)vs 14.2+/-4.8 APDs. min(-1), P<0.05) and delayed the onset of early reinitiation of atrial fibrillation (33+/-17s vs 11+/-11 s, P<0.05). Atrial pacing at 300 ms decreased the coupling interval of atrial premature depolarization as compared to no pacing and during atrial pacing at 500 ms (P<0.05), but without early reinitiation of atrial fibrillation suppression. Administration of intravenous sotalol was effective in preventing early reinitiation of atrial fibrillation in five of seven (71%) patients where pacing failed to suppress early reinitiation of atrial fibrillation.
CONCLUSION: The results of this study suggest that atrial pacing can be useful when combined with transvenous defibrillation in patients with early reinitiation of atrial fibrillation. Copyright 2000 The European Society of Cardiology.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10924300     DOI: 10.1053/euhj.1999.1991

Source DB:  PubMed          Journal:  Eur Heart J        ISSN: 0195-668X            Impact factor:   29.983


  3 in total

Review 1.  Pacing for atrial fibrillation.

Authors:  Chu-Pak Lau
Journal:  Heart       Date:  2003-01       Impact factor: 5.994

2.  [The role of cardiac pacing in atrial arrhythmia prevention].

Authors:  G Fröhlig
Journal:  Z Kardiol       Date:  2005

3.  Early reinitiation of atrial fibrillation following external electrical cardioversion in amiodarone-treated patients.

Authors:  C Reithmann; U Dorwarth; A Gerth; T Remp; G Steinbeck; E Hoffmann
Journal:  J Interv Card Electrophysiol       Date:  2001-09       Impact factor: 1.900

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.