Literature DB >> 10921649

Internal and external tibial rotation strength after anterior cruciate ligament reconstruction using ipsilateral semitendinosus and gracilis tendon autografts.

R W Viola1, W I Sterett, D Newfield, J R Steadman, M R Torry.   

Abstract

The internal and external tibial rotation torques of subjects who had undergone anterior cruciate ligament reconstruction using semitendinosus and gracilis tendon grafts were measured to determine whether harvest of the tendons results in weakness of tibial internal and external rotation. Cybex NORM dynamometer examinations were performed to measure internal and external tibial torque at angular velocities of 60, 120, and 180 deg/sec in 23 subjects. The sex-specific average torque data of the reconstructed limbs were compared with those of the contralateral limbs. Relative internal and external torque scores were calculated for each subject by subtracting the peak torque of the reconstructed knee from that of the contralateral knee. These relative scores were averaged and compared with the null hypothesis that each score should be statistically similar to zero. Subjects were evaluated at an average of 51 +/- 40 months postoperatively. The mean relative internal torque scores of the reconstructed limbs showed a statistically significant decrease from those of the contralateral limbs at all angular velocities. The mean relative external torque scores of the reconstructed limbs were statistically similar to those of the contralateral limbs at all angular velocities. Subjects who had undergone ligament reconstruction using semitendinosus and gracilis tendons demonstrated internal tibial rotation weakness in their reconstructed knees compared with their contralateral knees at all angular velocities tested. These results suggest that semitendinosus and gracilis tendon harvest causes weakness of internal tibial rotation.

Entities:  

Mesh:

Year:  2000        PMID: 10921649     DOI: 10.1177/03635465000280041801

Source DB:  PubMed          Journal:  Am J Sports Med        ISSN: 0363-5465            Impact factor:   6.202


  27 in total

1.  Anterior cruciate ligament reconstruction with double-looped semitendinosus and gracilis tendon graft directly fixed to cortical bone: 5-year results.

Authors:  Francesco Giron; Paolo Aglietti; Pierluigi Cuomo; Nicola Mondanelli; Antonio Ciardullo
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2004-10-16       Impact factor: 4.342

Review 2.  Hamstring tendons regeneration after ACL reconstruction: an overview.

Authors:  Vassilios S Nikolaou; Nicolas Efstathopoulos; Torsten Wredmark
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2006-08-18       Impact factor: 4.342

3.  All-epiphyseal, all-inside anterior cruciate ligament reconstruction technique for skeletally immature patients.

Authors:  Moira M McCarthy; Jessica Graziano; Daniel W Green; Frank A Cordasco
Journal:  Arthrosc Tech       Date:  2012-11-22

4.  Early regeneration determines long-term graft site morphology and function after reconstruction of the anterior cruciate ligament with semitendinosus-gracilis autograft: a case series.

Authors:  Toran D Macleod; Lynn Snyder-Mackler; Michael J Axe; Thomas S Buchanan
Journal:  Int J Sports Phys Ther       Date:  2013-06

5.  Hip flexion strength remains decreased in anterior cruciate ligament reconstructed patients at one-year follow up compared to healthy controls.

Authors:  Georgios Mouzopoulos; Rainer Siebold; Mathaios Tzurbakis
Journal:  Int Orthop       Date:  2015-02-03       Impact factor: 3.075

6.  Prospective comparison of auto and allograft hamstring tendon constructs for ACL reconstruction.

Authors:  Cory M Edgar; Scott Zimmer; Sanjeev Kakar; Hugh Jones; Anthony A Schepsis
Journal:  Clin Orthop Relat Res       Date:  2008-06-25       Impact factor: 4.176

7.  Knee flexor strength after ACL reconstruction: comparison between hamstring autograft, tibialis anterior allograft, and non-injured controls.

Authors:  Sarah Landes; John Nyland; Brian Elmlinger; Ed Tillett; David Caborn
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2009-11-07       Impact factor: 4.342

8.  Decrease of knee flexion torque in patients with ACL reconstruction: combined analysis of the architecture and function of the knee flexor muscles.

Authors:  Yukiko Makihara; Akie Nishino; Toru Fukubayashi; Akihiro Kanamori
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2005-10-06       Impact factor: 4.342

9.  Hamstring tendon anterior cruciate ligament reconstruction: does gracilis tendon harvest matter?

Authors:  Björn Barenius; Webster Kate Webster; Jodie McClelland; Julian Feller
Journal:  Int Orthop       Date:  2012-10-11       Impact factor: 3.075

10.  Quadruple Semitendinosus Graft Construct and Suspensory Button Fixation for Anterior Cruciate Ligament Reconstruction.

Authors:  Alcindo Silva; Ricardo Sampaio
Journal:  Arthrosc Tech       Date:  2015-12-10
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.