Literature DB >> 10920565

The force levels required to mechanically debond ceramic brackets: an in vitro comparative study.

S Arici1, C Minors.   

Abstract

The in vitro force levels generated by four differing methods of mechanical debonding techniques for ceramic brackets, using debonding pliers, were measured. The forces generated using wide (method W) and narrow blades (method N) were compared with those generated using a diagonally opposite corner application of the wide blades (method C) and incisal-gingival application of a pair of pointed blades (method P). Chemically retained ceramic brackets (Transcend) were bonded to bovine teeth using a filled, two-paste, chemically cured composite (Concise). After 24 hours storage at 37 degrees C in water, each specimen was subjected to one of the four mechanical debonding methods in a custom-built jig, simulating the clinical application of conventional debonding pliers. A one-way ANOVA with a Tukey's honestly significant difference test revealed statistically significant differences in debonding strengths between the four methods at the 0.05 level of significance. The mean debonding strength generated by method C was 40 and 25 per cent lower than that for methods W and N, respectively. Scoring of the adhesive remnant index (ARI) revealed that the predominant bond failure site was at the bracket/adhesive interface for all groups. Macroscopically, no enamel damage or bracket fractures were observed.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10920565     DOI: 10.1093/ejo/22.3.327

Source DB:  PubMed          Journal:  Eur J Orthod        ISSN: 0141-5387            Impact factor:   3.075


  3 in total

1.  CO2 laser as auxiliary in the debonding of ceramic brackets.

Authors:  Rodrigo Teixeira Macri; Fabrício Augusto de Lima; Luciano Bachmann; Rodrigo Galo; Fábio Lourenço Romano; Maria Cristina Borsatto; Mírian Aiko Nakane Matsumoto
Journal:  Lasers Med Sci       Date:  2014-11-20       Impact factor: 3.161

2.  Comparison of the Debonding Characteristics of Conventional and New Debonding Instrument used for Ceramic, Composite and Metallic Brackets - An Invitro Study.

Authors:  Garima Choudhary; Vikas Gill; Y N N Reddy; Sudhanshu Sanadhya; Pankaj Aapaliya; Nidhi Sharma
Journal:  J Clin Diagn Res       Date:  2014-07-20

3.  Influence of different tooth types on the bond strength of two orthodontic adhesive systems.

Authors:  Bora Oztürk; Siddik Malkoç; Alp Erdin Koyutürk; Bülent Catalbas; Füsun Ozer
Journal:  Eur J Orthod       Date:  2008-08       Impact factor: 3.075

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.