Literature DB >> 10919532

The accuracy of pulse oximetry in the emergency department.

W W Lee1, K Mayberry, R Crapo, R L Jensen.   

Abstract

The objective of this retrospective study was to identify factors affecting the accuracy of pulse oximetry in the ED. Over a 3-year period, 664 consecutive emergency department (ED) patients had simultaneous arterial blood gas (ABG) and pulse oximeter readings taken. Pulse oximeter saturations (SpO2) were compared with ABG CO-oximeter saturations (SaO2) for accuracy. Multiple variables including age, sex, hemoglobin, bicarbonate, pH, and carboxyhemoglobin (COHb) were analyzed to see if they affected SpO2 accuracy. ROC curves were used to determine the best pulse oximeter threshold for detecting hypoxia. Using multivariate analysis, COHb was the only statistically significant factor affecting the accuracy of pulse oximetry. In patients with COHb <2%, SpO2 overestimated SaO2 by more than 4% in 8.4% of cases. In patients with COHb > or = 2%, SpO2 overestimated SaO2 by more than 4% in 35% of cases. The best pulse oximetry threshold for detecting hypoxia is 92%. At this threshold, if COHb is <2%, pulse oximetry has a sensitivity of 0.92 and specificity of 0.90. If COHb is > or =2%, sensitivity is 0.74 and specificity is 0.84. For patients likely to have a COHb < 2, pulse oximetry is an effective screening tool for detecting hypoxia. However, more caution must be exercised when using pulse oximetry in patients likely to have a COHb > or = 2%.

Entities:  

Mesh:

Year:  2000        PMID: 10919532     DOI: 10.1053/ajem.2000.7330

Source DB:  PubMed          Journal:  Am J Emerg Med        ISSN: 0735-6757            Impact factor:   2.469


  20 in total

1.  The role of pulse oximetry in chiropractic practice: a rationale for its use.

Authors:  Michael W Hall; Anne M Jensen
Journal:  J Chiropr Med       Date:  2012-06

Review 2.  Asthma outcomes: pulmonary physiology.

Authors:  Robert S Tepper; Robert S Wise; Ronina Covar; Charles G Irvin; Carolyn M Kercsmar; Monica Kraft; Mark C Liu; George T O'Connor; Stephen P Peters; Ronald Sorkness; Alkis Togias
Journal:  J Allergy Clin Immunol       Date:  2012-03       Impact factor: 10.793

3.  Comparative Evaluation of Accuracy of Pulse Oximeters and Factors Affecting Their Performance in a Tertiary Intensive Care Unit.

Authors:  Anupam Kumar Singh; Malvinder Singh Sahi; Bablesh Mahawar; Sajjan Rajpurohit
Journal:  J Clin Diagn Res       Date:  2017-06-01

4.  The incidence of hypoxemia during surgery: evidence from two institutions.

Authors:  Jesse M Ehrenfeld; Luke M Funk; Johan Van Schalkwyk; Alan F Merry; Warren S Sandberg; Atul Gawande
Journal:  Can J Anaesth       Date:  2010-07-31       Impact factor: 5.063

5.  Emergency Department Vital Signs and Outcomes After Discharge.

Authors:  Gelareh Z Gabayan; Michael K Gould; Robert E Weiss; Stephen F Derose; Vicki Y Chiu; Catherine A Sarkisian
Journal:  Acad Emerg Med       Date:  2017-07       Impact factor: 3.451

6.  Pathogenesis of neonatal necrotizing enterocolitis: a study of the role of intraluminal pressure, age and bacterial concentration.

Authors:  K L Chan; S P Ng; K W Chan; Y H Wo; P K H Tam
Journal:  Pediatr Surg Int       Date:  2003-10-09       Impact factor: 1.827

7.  The accuracy of pulse oximetry in emergency department patients with severe sepsis and septic shock: a retrospective cohort study.

Authors:  Ben J Wilson; Hamish J Cowan; Jason A Lord; Dan J Zuege; David A Zygun
Journal:  BMC Emerg Med       Date:  2010-05-05

8.  The Epidemiology of Hypoxemic Pneumonia among Young Infants in Malawi.

Authors:  Shubhada Hooli; Carina King; Beatiwel Zadutsa; Bejoy Nambiar; Charles Makwenda; Gibson Masache; Norman Lufesi; Charles Mwansambo; Lucas Malla; Anthony Costello; Tim Colbourn; Eric D McCollum
Journal:  Am J Trop Med Hyg       Date:  2020-03       Impact factor: 2.345

9.  Increased blood glycohemoglobin A1c levels lead to overestimation of arterial oxygen saturation by pulse oximetry in patients with type 2 diabetes.

Authors:  Li Jin Pu; Ying Shen; Lin Lu; Rui Yan Zhang; Qi Zhang; Wei Feng Shen
Journal:  Cardiovasc Diabetol       Date:  2012-09-17       Impact factor: 9.951

10.  Smoke inhalation lung injury: an update.

Authors:  Robert H Demling
Journal:  Eplasty       Date:  2008-05-16
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.