Literature DB >> 10918333

3D interleaved water and fat image acquisition with chemical-shift correction.

W E Kwok1, S M Totterman, J Zhong.   

Abstract

A new technique, 3D interleaved water and fat image acquisition with chemical-shift correction (3-DIWFAC), was developed to acquire 3D water and fat images in a single acquisition time and to combine the water and fat images to produce chemical-shift-free images. A 3D gradient-recalled-echo (GRE) sequence was implemented with a 1-3-3-1 binomial Shinnar-Le Roux spatial-spectral excitation, and with interleaved phase-encoding lines that alternate between water and fat excitations separated by half TR. Water-only and fat-only images were then realigned to remove chemical shift artifacts. Results from phantoms and human subjects demonstrated that the image contrast was the same as in the regular GRE sequence. With the chemical shift corrected, the shadow artifacts often seen at water and fat boundaries were removed. Since this sequence simultaneously provides water-only images showing cartilage and bone lesions, and water-fat images that depict soft tissue anatomy, it may be clinically useful in musculoskeletal imaging. Magn Reson Med 44:322-330, 2000. Copyright 2000 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2000        PMID: 10918333     DOI: 10.1002/1522-2594(200008)44:2<322::aid-mrm21>3.0.co;2-q

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  4 in total

1.  High-resolution interleaved water-fat MR imaging of finger joints with chemical-shift elimination.

Authors:  Wingchi E Kwok; Zhigang You; Gwysuk Seo; Amy Lerner; Saara Totterman; Christopher Ritchlin; Johnny Monu
Journal:  J Magn Reson Imaging       Date:  2011-01       Impact factor: 4.813

2.  Subchondral bone and cartilage thickness from MRI: effects of chemical-shift artifact.

Authors:  Chris A McGibbon; Jenny Bencardino; William E Palmer
Journal:  MAGMA       Date:  2003-02       Impact factor: 2.310

3.  In vivo lactate signal enhancement using binomial spectral-selective pulses in selective MQ coherence (SS-SelMQC) spectroscopy.

Authors:  S B Thakur; J Yaligar; J A Koutcher
Journal:  Magn Reson Med       Date:  2009-09       Impact factor: 4.668

4.  A Comparative Study of High-Resolution Chemical-Shift-Eliminated Magnetic Resonance Imaging of Finger Specimens with Microcomputed Tomography.

Authors:  Wingchi Edmund Kwok; Zhigang You; Johnny Monu; Hua He
Journal:  J Clin Imaging Sci       Date:  2019-05-24
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.