Air blast circuit breaker noise and hearing loss: a multifactorial model for risk assessment.

D I McBride1, S Williams.   

Abstract

The assessment of the risk to hearing from impulse noise exposure may be a problem for the occupational physician because existing legislative and international noise exposure standards deal primarily with continuous noise, and are not valid in excess of the peak exposure limit of 200 pa (140 dB). Noise exposure in excess of this level, for example that due to firearms, is frequently perceived as harmful, but this is not necessarily the case, as impulse noise standards do, in fact, allow exposure with a maximum in the order of 6.3 kPa (170 dB). To illustrate this, a cross-sectional group of electrical transmission workers have been studied who were exposed to significant levels of impulse noise from air blast circuit breakers and firearms. Important hearing loss factors have been identified by means of a specially designed questionnaire. Using the Health & Safety Executive definition, the risk of hearing loss was determined by calculating prevalence odds ratios (ORs) for exposure to these factors. The OR for those with fewer than eight unprotected air blast circuit breaker exposures was 2.27 (95% confidence interval (CI), 1.01-5.08), whilst for those with more than eight exposures the OR was 2.10 (95% CI, 0.97-4.54). For firearm exposure, ORs of 1.61 (95% CI, 0.95-2.74) were noted in the medium exposure group and 2.05 (95% CI, 1.08-3.86) in the high exposure group. When all the factors were included in the model, the most significant factor was age. The study gives support to the impulse noise exposure criteria, confirming the borderline risk from air blast circuit breaker noise exposure and the relative safety of moderate gunfire exposure.

Entities:  

Mesh:

Year:  2000        PMID: 10912360     DOI: 10.1093/occmed/50.3.173

Source DB:  PubMed          Journal:  Occup Med (Lond)        ISSN: 0962-7480            Impact factor:   1.611


  2 in total

1.  Audiometric notch as a sign of noise induced hearing loss.

Authors:  D I McBride; S Williams
Journal:  Occup Environ Med       Date:  2001-01       Impact factor: 4.402

Review 2.  Occupational noise exposure and hearing: a systematic review.

Authors:  Arve Lie; Marit Skogstad; Håkon A Johannessen; Tore Tynes; Ingrid Sivesind Mehlum; Karl-Christian Nordby; Bo Engdahl; Kristian Tambs
Journal:  Int Arch Occup Environ Health       Date:  2015-08-07       Impact factor: 3.015

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.