PURPOSE: Colonic motility is crucial for the resolution of postoperative ileus. However, few data are available on postoperative colonic motility and no data on postoperative colonic tone. We aimed to characterize postoperative colonic tone and motility in patients. METHODS: Nineteen patients were investigated with combined barostat and manometry recordings after left colonic surgery. During surgery a combined recording catheter was placed in the colon with two barostat bags and four manometry channels cephalad to the anastomosis. Recordings were performed twice daily from Day 1 to Day 3 after surgery. RESULTS: Manometry showed an increasing colonic motility index, which was a mean (+/- standard error of the mean) of 37 +/- 5 mmHg/minute on Day 1, 87 +/- 19 mmHg/minute on Day 2, and 102 +/- 13 mmHg/minute on Day 3 (P < 0.05 for Day 1 vs. Day 2 and Day 2 vs. Day 3). Low barostat bag volumes indicating a high colonic tone were observed on Day 1 after surgery and increased subsequently (barostat bag I was 19 +/- 4, 32 +/- 6, and 32 +/- 6 ml; barostat bag II was 13 +/- 1, 19 +/- 3, and 22 +/- 5 ml on Days 1, 2, and 3, respectively; for both barostat bags P < 0.05 for Day 1 vs. Day 2 but not Day 2 vs. Day 3). CONCLUSIONS: Colonic motility increased during the postoperative course. The low barostat bag volumes indicated a high colonic tone postoperatively which would correspond to a contracted rather than to a distended colon. High colonic tone postoperatively may be relevant for pharmacologic treatment of postoperative ileus.
PURPOSE:Colonic motility is crucial for the resolution of postoperative ileus. However, few data are available on postoperative colonic motility and no data on postoperative colonic tone. We aimed to characterize postoperative colonic tone and motility in patients. METHODS: Nineteen patients were investigated with combined barostat and manometry recordings after left colonic surgery. During surgery a combined recording catheter was placed in the colon with two barostat bags and four manometry channels cephalad to the anastomosis. Recordings were performed twice daily from Day 1 to Day 3 after surgery. RESULTS: Manometry showed an increasing colonic motility index, which was a mean (+/- standard error of the mean) of 37 +/- 5 mmHg/minute on Day 1, 87 +/- 19 mmHg/minute on Day 2, and 102 +/- 13 mmHg/minute on Day 3 (P < 0.05 for Day 1 vs. Day 2 and Day 2 vs. Day 3). Low barostat bag volumes indicating a high colonic tone were observed on Day 1 after surgery and increased subsequently (barostat bag I was 19 +/- 4, 32 +/- 6, and 32 +/- 6 ml; barostat bag II was 13 +/- 1, 19 +/- 3, and 22 +/- 5 ml on Days 1, 2, and 3, respectively; for both barostat bags P < 0.05 for Day 1 vs. Day 2 but not Day 2 vs. Day 3). CONCLUSIONS:Colonic motility increased during the postoperative course. The low barostat bag volumes indicated a high colonic tone postoperatively which would correspond to a contracted rather than to a distended colon. High colonic tone postoperatively may be relevant for pharmacologic treatment of postoperative ileus.
Authors: R Vather; G O'Grady; A Y Lin; P Du; C I Wells; D Rowbotham; J Arkwright; L K Cheng; P G Dinning; I P Bissett Journal: Br J Surg Date: 2018-04-14 Impact factor: 6.939
Authors: Mario H Mueller; Martina Karpitschka; Zhirong Gao; Sarah Mittler; Michael S Kasparek; Bernhard Renz; Andrej Sibaev; Jörg Glatzle; Yongyu Li; Martin E Kreis Journal: J Gastrointest Surg Date: 2011-03-25 Impact factor: 3.452
Authors: M H Mueller; M Karpitschka; B Xue; M S Kasparek; A Sibaev; J Glatzle; M E Kreis Journal: J Gastrointest Surg Date: 2009-01-07 Impact factor: 3.452
Authors: Michael S Kasparek; Joerg Glatzle; Mario H Mueller; Andreas Vogt; Alfred Koenigsrainer; Tilman T Zittel; Martin E Kreis Journal: Int J Colorectal Dis Date: 2006-08-29 Impact factor: 2.796
Authors: Michael S Kasparek; Mario H Müller; Jörg Glatzle; Klaus Manncke; Horst D Becker; Tilman T Zittel; Martin E Kreis Journal: J Gastrointest Surg Date: 2003-12 Impact factor: 3.267