Fast maximum entropy approximation in SPECT using the RBI-MAP algorithm.

D S Lalush1, E C Frey, B M Tsui.   

Abstract

In this work, we present a method for approximating constrained maximum entropy (ME) reconstructions of SPECT data with modifications to a block-iterative maximum a posteriori (MAP) algorithm. Maximum likelihood (ML)-based reconstruction algorithms require some form of noise smoothing. Constrained ME provides a more formal method of noise smoothing without requiring the user to select parameters. In the context of SPECT, constrained ME seeks the minimum-information image estimate among those whose projections are a given distance from the noisy measured data, with that distance determined by the magnitude of the Poisson noise. Images that meet the distance criterion are referred to as feasible images. We find that modeling of all principal degrading factors (attenuation, detector response, and scatter) in the reconstruction is critical because feasibility is not meaningful unless the projection model is as accurate as possible. Because the constrained ME solution is the same as a MAP solution for a particular value of the MAP weighting parameter, beta, the constrained ME solution can be found with a MAP algorithm if the correct value of beta is found. We show that the RBI-MAP algorithm, if used with a dynamic scheme for estimating beta, can approximate constrained ME solutions in 20 or fewer iterations. We compare results for various methods of achieving feasible images on a simulation of Tl-201 cardiac SPECT data. Results show that the RBI-MAP ME approximation provides images and quantitative estimates close to those from a slower algorithm that gives the true ME solution. Also, we find that the ME results have higher spatial resolution and greater high-frequency noise content than a feasibility-based stopping rule, feasibility-based low-pass filtering, and a quadratic Gibbs prior with beta selected according to the feasibility criterion. We conclude that fast ME approximation is possible using either RBI-MAP with the dynamic procedure or a feasibility-based stopping rule, and that such reconstructions may be particularly useful in applications where resolution is critical.

Entities:  

Mesh:

Year:  2000        PMID: 10909924     DOI: 10.1109/42.848180

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  5 in total

1.  In vivo tumor angiogenesis imaging with site-specific labeled (99m)Tc-HYNIC-VEGF.

Authors:  Francis G Blankenberg; Marina V Backer; Zoia Levashova; Vimalkumar Patel; Joseph M Backer
Journal:  Eur J Nucl Med Mol Imaging       Date:  2006-07       Impact factor: 9.236

2.  Image reconstruction for PET/CT scanners: past achievements and future challenges.

Authors:  Shan Tong; Adam M Alessio; Paul E Kinahan
Journal:  Imaging Med       Date:  2010-10-01

3.  99mTc-HYNIC-annexin V SPECT imaging of acute stroke and its response to neuroprotective therapy with anti-Fas ligand antibody.

Authors:  Francis G Blankenberg; Judy Kalinyak; Liping Liu; Maya Koike; Danye Cheng; Michael L Goris; Allan Green; Jean-Luc Vanderheyden; David C Tong; Midori Anne Yenari
Journal:  Eur J Nucl Med Mol Imaging       Date:  2006-02-14       Impact factor: 9.236

4.  Detection of focal hypoxic-ischemic injury and neuronal stress in a rodent model of unilateral MCA occlusion/reperfusion using radiolabeled annexin V.

Authors:  Carina Mari; Murat Karabiyikoglu; Michael L Goris; Jonathan F Tait; Midori Anne Yenari; Francis G Blankenberg
Journal:  Eur J Nucl Med Mol Imaging       Date:  2004-02-21       Impact factor: 9.236

5.  Experimental investigation of angular stackgram filtering for noise reduction of SPECT projection data: study with linear and nonlinear filters.

Authors:  Antti P Happonen; Matti O Koskinen
Journal:  Int J Biomed Imaging       Date:  2007
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.