| Literature DB >> 10901148 |
N Bleyzac1, P Barou, G Aulagner.
Abstract
A reversed-phase liquid chromatographic method with ultraviolet detection has been developed to determine busulfan concentrations in plasma of children undergoing bone marrow transplantation. Plasma samples (200 microl) containing busulfan and 1,6-bis(methanesulfonyloxy)hexane as an internal standard were prepared by a simple derivatization method with diethyldithiocarbamate followed by extraction with ethyl acetate and solid-phase purification on C8 columns conditioned with methanol and water and eluted with acetonitrile (recovery 99%). Chromatography was accomplished using a Hypersil octadecylsilyl column (10 cm x 4.6 mm I.D.) and a mobile phase of acetonitrile, tetrahydrofuran and distilled water (65:5:30, v/v). The limit of detection was 25 ng/ml (signal-to-noise ratio of 5). Calibration curves were linear up to 25,000 ng/ml. Intra-day and inter-day coefficients of variation of the assay were < or =5%. This method was used to analyse busulfan plasma concentrations after oral administration within the framework of therapeutic drug monitoring and pharmacokinetic studies in children.Entities:
Mesh:
Substances:
Year: 2000 PMID: 10901148 DOI: 10.1016/s0378-4347(00)00167-5
Source DB: PubMed Journal: J Chromatogr B Biomed Sci Appl ISSN: 1387-2273