Abstract
A column-switching high-performance liquid chromatographic method for the simultaneous determination of five frequently prescribed benzodiazepines: clonazepam, diazepam, flunitrazepam, midazolam and oxazepam was developed. A 50-microl plasma sample was directly injected into a BioTrap 500 MS (hydrophobic polymer) column. After a washing step with a mixture of phosphate buffer and acetonitrile, the retained benzodiazepines were back-flushed into a reversed-phase (LiChrospher Select B C8) column with a mobile phase of acetonitrile-phosphate buffer. The method showed excellent linearity from 50 to 1000 ng/ml for clonazepam, flunitrazepam and midazolam and from 50 to 5000 ng/ml for diazepam and oxazepam. The recoveries were around 98% for all the benzodiazepines studied. The relative standard deviation for between-and within-day assay was <20% for low concentrations close to the values of the limit of quantification and <4% for high concentrations. The procedure described is relatively simple and rapid because no off-line manipulation of the sample is required: the total analysis time is approximately 30 min.Entities: