Literature DB >> 10898841

Changes in the edentulous maxilla in persons wearing implant-retained mandibular overdentures.

T O Närhi1, M E Geertman, M Hevinga, H Abdo, W Kalk.   

Abstract

STATEMENT OF PROBLEM: It has been suggested that risk for severe resorption in the anterior maxilla is increased in persons wearing mandibular implant-retained overdentures. However, little information is available about the changes in the edentulous maxilla after mandibular implant treatment.
PURPOSE: This study determined the possible changes in the width of the maxillary residual ridge 6 years after receiving mandibular implant-supported or implant-mucosa-supported overdentures and evaluated the association between the anatomic changes and subjective complaints with maxillary complete dentures. METHODS AND MATERIAL: The subjects for this study (n = 55), enrolled among the participants of a prospective clinical trial, were randomly assigned into 3 groups treated with: (a) implant-supported overdentures on a transmandibular implant system (n = 21); (b) implant-mucosa-supported overdentures on 2 IMZ implants (n = 20); or (c) conventional complete dentures (n = 14). A lingual contact occlusion concept with anterior open bite was used for tooth arrangement in all subjects. Diagnostic casts were made at baseline, and again at the 6-year follow-up. Most prominent points perpendicular to the crest of residual ridge were located in the incisor, canine, and premolar regions, after which the width of the ridge was recorded at these points with a Boley gage. Subjects' opinions on their dentures were evaluated with a questionnaire.
RESULTS: Significant reduction in the width of the ridge was found in all measurement areas (mean difference = 0.4 to 0.6 mm; P <.0001). However, changes were small and not associated with the type of prosthetic restoration in the mandible. In subjects with implant-mucosa-supported overdentures, complaint of loose maxillary denture correlated with the decrement of residual ridge width.
CONCLUSION: The width of residual ridge decreases with time, despite the type of mandibular prosthetic restoration.

Entities:  

Mesh:

Year:  2000        PMID: 10898841     DOI: 10.1067/mpr.2000.107113

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  4 in total

1.  Comparison of ridge resorption and patient satisfaction in single implant-supported mandibular overdentures with conventional complete dentures: A randomised pilot study.

Authors:  Subin Km; Dheeraj Kumar Koli; Veena Jain; Gunjan Pruthi; Aditi Nanda
Journal:  J Oral Biol Craniofac Res       Date:  2020-11-25

2.  Comparison of retentive force and wear pattern of Locator® and ADD-TOC attachments combined with CAD-CAM milled bar.

Authors:  Sung-Ki Chae; Won-Tak Cho; Jae-Won Choi; Eun-Bin Bae; Ji-Hyeon Bae; Gang-Ho Bae; Jung-Bo Huh
Journal:  J Adv Prosthodont       Date:  2022-02-25       Impact factor: 1.904

3.  Assessment of the prevalence index on signs of combination syndrome in patients treated at Bauru School of Dentistry, University of Sao Paulo.

Authors:  Milton Carlos Gonçalves Salvador; Accácio Lins do Valle; Mariana Carvalho Mandim Ribeiro; Jefferson Ricardo Pereira
Journal:  J Appl Oral Sci       Date:  2007-02       Impact factor: 2.698

4.  Comparison of masticatory efficiency, patient satisfaction for single, two, and three implants supported overdenture in the same patient: A pilot study.

Authors:  Srinidhi Bhat; Ramesh Chowdhary; Sudhindra Mahoorkar
Journal:  J Indian Prosthodont Soc       Date:  2016 Apr-Jun
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.