Literature DB >> 10898839

Effect of ring liner and casting ring temperature on the dimension of cast posts.

R Del Castillo1, C Ercoli, G N Graser, R H Tallents, M E Moss.   

Abstract

STATEMENT OF PROBLEM: If a post does not fit passively, binding with the radicular tooth structure occurs, possibly increasing the risk for root fracture. Therefore, it is necessary to fabricate slightly undersized cast posts to allow for passive fit and cement placement. Shrinkage of the mold cavity may be a desired effect during the casting of posts.
PURPOSE: This study evaluated the influence of: (1) a cellulose ring liner, and (2) a lower casting temperature of the metal ring, on the dimensions of a cast post.
MATERIAL AND METHODS: Eighty plastic posts were divided in 4 equal groups (group 1, 815 degrees C, liner; group 2, 815 degrees C, no liner; group 3, 600 degrees C, liner; and group 4, 600 degrees C, no liner), invested in phosphate-bonded investment and cast with a noble alloy. Posts were measured at 2 locations, the tip and base, before and after casting.
RESULTS: Investing in a lined metal ring and using a casting ring temperature of 815 degrees C (group 1) resulted in markedly oversized posts (tip: +25.8 microm; base: +20.3 microm). The absence of the cellulose liner in the casting ring (group 2) decreased the expansion of the investment producing slightly oversized castings (tip: +9.75 microm; base: +4.52 microm). Lined rings that were heated to a final temperature of 600 degrees C (group 3) produced posts that were oversized (tip: +16.65 microm; base: +11.05 microm). Final casting ring temperature of 600 degrees C and the absence of a cellulose liner (group 4) resulted in posts slightly undersized (tip: -4.1 microm; base: -2.2 microm).
CONCLUSION: The use of 2 casting ring temperatures (815 degrees C or 600 degrees C) and the influence of a ring liner were investigated. Decreasing the casting ring temperature from 815 degrees C to 600 degrees C and the absence of a ring liner significantly decreased the dimensions of a cast post.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10898839     DOI: 10.1067/mpr.2000.107913

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  2 in total

1.  Impact of a Core Ferrule Design on Fracture Resistance of Teeth Restored with Cast Post and Core.

Authors:  Loubna Shamseddine; Farid Chaaban
Journal:  Adv Med       Date:  2016-06-22

2.  In vitro assessment of retention and resistance failure loads of complete coverage restorations made for anterior maxillary teeth restored with two different cast post and core designs.

Authors:  Efpraxia Bakirtzoglou; Savvas N Kamalakidis; Argirios L Pissiotis; Konstantinos Michalakis
Journal:  J Clin Exp Dent       Date:  2019-03-01
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.