Literature DB >> 10898037

Blood pool and liver enhancement in CT with liposomal lodixanol: comparison with lohexol.

T S Desser1, D L Rubin, H Muller, G L McIntire, E R Bacon, J L Toner.   

Abstract

RATIONALE AND
OBJECTIVES: The authors compared the time course and blood pool and hepatic enhancement of three different doses of liposomal iodixanol with those of iohexol.
MATERIALS AND METHODS: A liposomal iodixanol formulation was prepared with 200 mg of iodine per milliliter total and 80 mg of iodine per milliliter encapsulated. Twelve normal New Zealand white rabbits divided into four groups received 75-, 100-, or 150-mg encapsulated iodine per kilogram doses of liposomal iodixanol or 2 mL/kg iohexol with 300 mg of iodine per milliliter. A liver section was scanned with serial computed tomography (CT) before the injection, immediately afterward, and at 1-minute intervals for 10 minutes. Region-of-interest measurements of the aorta and liver were plotted at each time point, and contrast enhancement was plotted as a function of time and iodine dose.
RESULTS: All liposomal iodixanol doses produced greater liver enhancement than iohexol. Results were significant (P < .05) for 100 mg and 150 mg iodine per kilogram dose groups at time points beyond 2 minutes. Peak hepatic enhancement (change in attenuation) was 54.9 HU +/- 7.6 with iohexol, compared with 59.6 HU +/- 6.1, 73.3 HU +/- 3.6, and 104.1 HU +/- 8.8 for 75, 100, and 150 mg encapsulated iodine per kilogram doses, respectively. Hepatic enhancement increased rapidly after injection of liposomal iodixanol, plateauing 2-3 minutes later. Blood pool enhancement decreased rapidly. Steady-state liver enhancement with liposomal iodixanol increased linearly with dose. Aortic enhancement was greater with iohexol.
CONCLUSION: Liposomal iodixanol yielded greater hepatic enhancement at lower total iodine doses than iohexol. Although liver enhancement occurred rapidly after injection, blood pool enhancement was brief.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10898037     DOI: 10.1016/S1076-6332(99)80404-8

Source DB:  PubMed          Journal:  Acad Radiol        ISSN: 1076-6332            Impact factor:   3.173


  12 in total

1.  Time-course of contrast enhancement in spleen and liver with Exia 160, Fenestra LC, and VC.

Authors:  Inneke Willekens; Tony Lahoutte; Nico Buls; Christian Vanhove; Rudi Deklerck; Axel Bossuyt; Johan de Mey
Journal:  Mol Imaging Biol       Date:  2008-12-06       Impact factor: 3.488

Review 2.  Nanotechnology for computed tomography: a real potential recently disclosed.

Authors:  Nicolas Anton; Thierry F Vandamme
Journal:  Pharm Res       Date:  2013-07-30       Impact factor: 4.200

Review 3.  High-resolution CT vascular imaging using blood pool contrast agents.

Authors:  Ananth V Annapragada; Eric Hoffman; Abhay Divekar; Efstathios Karathanasis; Ketan B Ghaghada
Journal:  Methodist Debakey Cardiovasc J       Date:  2012-01

4.  Liposomes coloaded with iopamidol/lipiodol as a RES-targeted contrast agent for computed tomography imaging.

Authors:  Soonjae Kweon; Ho-Joon Lee; Woo Jin Hyung; Jinsuk Suh; Joon Seok Lim; Soo-Jeong Lim
Journal:  Pharm Res       Date:  2010-04-28       Impact factor: 4.200

5.  Imaging of pulmonary embolism and t-PA therapy effects using MDCT and liposomal iohexol blood pool agent: preliminary results in a rabbit model.

Authors:  Stephen J Burke; Ananth Annapragada; Eric A Hoffman; Emmanuel Chen; Ketan B Ghaghada; Jered Sieren; Edwin J R van Beek
Journal:  Acad Radiol       Date:  2007-03       Impact factor: 3.173

Review 6.  X-ray-computed tomography contrast agents.

Authors:  Hrvoje Lusic; Mark W Grinstaff
Journal:  Chem Rev       Date:  2012-12-05       Impact factor: 60.622

Review 7.  Applications of nanoparticles for diagnosis and therapy of cancer.

Authors:  S C Baetke; T Lammers; F Kiessling
Journal:  Br J Radiol       Date:  2015-06-12       Impact factor: 3.039

8.  Erbium-Based Perfusion Contrast Agent for Small-Animal Microvessel Imaging.

Authors:  Justin J Tse; P Joy Dunmore-Buyze; Maria Drangova; David W Holdsworth
Journal:  Contrast Media Mol Imaging       Date:  2017-11-15       Impact factor: 3.161

9.  Remote loading of liposomes with a 124I-radioiodinated compound and their in vivo evaluation by PET/CT in a murine tumor model.

Authors:  Gokce Engudar; Henrik Schaarup-Jensen; Frederikke P Fliedner; Anders E Hansen; Paul Kempen; Rasmus I Jølck; Andreas Kjæer; Thomas L Andresen; Mads H Clausen; Andreas I Jensen; Jonas R Henriksen
Journal:  Theranostics       Date:  2018-11-12       Impact factor: 11.556

Review 10.  Nanoparticles for imaging: top or flop?

Authors:  Fabian Kiessling; Marianne E Mertens; Jan Grimm; Twan Lammers
Journal:  Radiology       Date:  2014-10       Impact factor: 11.105

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.