Literature DB >> 10894903

Using internal jugular pulsations as a manometer for right atrial pressure measurements.

J Constant1.   

Abstract

External jugulars are not reliable as an indication of right atrial pressure because of their passage through two right angles and also because they are often not visible. The top level of internal jugular pulsations which are transmitted to the skin of the neck serves as a pulsation manometer. A standard chest angle of 45 degrees and a standard zero at the sternal angle can be used together with a centimeter ruler to give a useful measurement of jugular venous pressure. The use of a carpenter level (spirit level) and a round-bottomed tongue blade measured off in centimeters will allow accurate follow-up. An increase in tone-volume can be detected by the abdominal compression test or abdominojugular test (also known by the outdated terminology of hepatojugular reflux). Copyright 2000 S. Karger AG, Basel

Mesh:

Year:  2000        PMID: 10894903     DOI: 10.1159/000006998

Source DB:  PubMed          Journal:  Cardiology        ISSN: 0008-6312            Impact factor:   1.869


  6 in total

1.  Jugular Venous Flow Quantification Using Doppler Sonography.

Authors:  Karen Marr; Dejan Jakimovski; Marcello Mancini; Ellen Carl; Robert Zivadinov
Journal:  Ultrasound Med Biol       Date:  2018-05-18       Impact factor: 2.998

Review 2.  The jugular venous pressure revisited.

Authors:  John Michael S Chua Chiaco; Nisha I Parikh; David J Fergusson
Journal:  Cleve Clin J Med       Date:  2013-10       Impact factor: 2.321

3.  A Novel Non-Invasive Device for the Assessment of Central Venous Pressure in Hospital, Office and Home.

Authors:  Emanuela Marcelli; Laura Cercenelli; Barbara Bortolani; Saverio Marini; Luca Arfilli; Alessandro Capucci; Gianni Plicchi
Journal:  Med Devices (Auckl)       Date:  2021-05-13

4.  Jugular vein distensibility predicts fluid responsiveness in septic patients.

Authors:  Fabio Guarracino; Baldassarre Ferro; Francesco Forfori; Pietro Bertini; Luana Magliacano; Michael R Pinsky
Journal:  Crit Care       Date:  2014-12-05       Impact factor: 9.097

5.  Central Venous Pressure Monitoring; Introduction of a New Device.

Authors:  Mahmood Ghafoori Yazdi; Arya Shoghli; Sina Faghihi; Alireza Baratloo
Journal:  Emerg (Tehran)       Date:  2016

6.  Internal jugular vein variability predicts fluid responsiveness in cardiac surgical patients with mechanical ventilation.

Authors:  Guo-Guang Ma; Guang-Wei Hao; Xiao-Mei Yang; Du-Ming Zhu; Lan Liu; Hua Liu; Guo-Wei Tu; Zhe Luo
Journal:  Ann Intensive Care       Date:  2018-01-16       Impact factor: 6.925

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.