Special problems in aerosol delivery: artificial airways.

R Dhand1.   

Abstract

Several factors interact in influencing aerosol deposition during mechanical ventilation. Among these factors, the artificial airway is a significant barrier for aerosol deposition. Earlier studies overemphasized the impediments created by the artificial airway to aerosol delivery, because the aerosol generator was placed adjacent to the endotracheal tube or was connected to it. When the aerosol generator is placed away from the endotracheal tube, the fraction that deposits within the tube is reduced and greater aerosol deposition occurs in the lungs. The type of aerosol generator used and the ventilator settings have a greater effect than the size of the tube on the amount of aerosol that deposits in the artificial airway. To minimize aerosol loss within artificial airways, an endotracheal tube of the appropriate size should be selected. "Priming" the tube with a few doses of aerosol before use decreases the electrostatic charge on its walls and may reduce aerosol deposition within the tube. Similarly, using a spacer with the MDI, and placement of the combination in the inspiratory limb at a distance of at least 15 cm from the endotracheal tube reduces aerosol loss within the endotracheal tube. Use of nebulizers that produce submicronic aerosols, and placing them closer to the ventilator instead of closer to the patient also decreases aerosol impaction in the artificial airway. Use of a low inspiratory flow (30-60 L/min in adults), higher duty cycle (> 0.3), and helium-oxygen mixture instead of air or oxygen are other measures to reduce aerosol loss in the airway and thereby improve aerosol delivery to the lower respiratory tract of mechanically ventilated patients.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10894456

Source DB:  PubMed          Journal:  Respir Care        ISSN: 0020-1324            Impact factor:   2.258


  4 in total

Review 1.  Aerosol delivery to ventilated newborn infants: historical challenges and new directions.

Authors:  Jan Mazela; Richard A Polin
Journal:  Eur J Pediatr       Date:  2010-09-28       Impact factor: 3.183

Review 2.  Administration of dry powders during respiratory supports.

Authors:  Wei-Ren Ke; Rachel Yoon Kyung Chang; Philip Chi Lip Kwok; Patricia Tang; Lan Chen; Donghao Chen; Hak-Kim Chan
Journal:  Ann Transl Med       Date:  2021-04

3.  Comparison between pressure support ventilation and T-piece in spontaneous breathing trials.

Authors:  Soo Jin Na; Ryoung-Eun Ko; Jimyoung Nam; Myeong Gyun Ko; Kyeongman Jeon
Journal:  Respir Res       Date:  2022-02-07

Review 4.  Nebulized antibiotics in mechanically ventilated patients: a challenge for translational research from technology to clinical care.

Authors:  Stephan Ehrmann; Jean Chastre; Patrice Diot; Qin Lu
Journal:  Ann Intensive Care       Date:  2017-08-01       Impact factor: 6.925

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.